WST-211 Wireless Contact with Local Bypass 

 

Specifications 

Frequency: 319.5MHz  

 

 

Operating Temperature: 32°-120°F (0°-49°C) 

Battery: 3V lithium CR2032    

 

Operating Humidity: 5-95% RH non condensing 

Battery life: 5-8 years  

 

 

Compatible with GE/Interlogix receivers 

Magnet gap: 5/8

th

 inch max   

 

Supervisory signal interval: 60min (approx.) 

 
Enrolling 

To enroll the sensor, set your panel into program mode, then go to the Learn Sensors menu. Refer 
to your specific alarm panel manual for details on these menus. To activate the case tamper 
simply slide the cover up and down, you will hear a click when the case latches are engaging and 
disengaging. Continue until the panel responds to the sensor. Then select the appropriate sensor 
group and number.  

 

Bypass Enable/Disable 

By default the bypass switch is disabled. To enable this feature, press and hold the bypass button 
while installing the battery. The LED will flash twice to indicate bypass is enabled. To disable the 
bypass, press and hold the button while installing the battery, the LED will flash once. 
 

Bypass Operation

 

To bypass the sensor, the door or window being protected must be in the closed position. Press 
and hold the bypass button until the LED starts to flash, then open the door or window. The LED 
will flash once every 10 seconds to indicate that the sensor is in bypass mode. To remove the 
bypass and restore normal operation, simply close the door or window.  

 
Mounting 

Included with the contact is double sided tape for the contact and the magnet. For reliable 
bonding ensure the surface is clean and dry. Apply the tape to the sensor and then to the desired 
location. Apply firm pressure for several seconds. It is not recommended to mount the tape at 
temperatures below 50°F, although after 24 hours the bond will hold at low temperatures. 
 
One side of the sensor is marked with 3 lines; this indicates the location of the reed switch. The 
magnet should be mounted facing this side of the sensor, and it must be no further than 5/8 of an 
inch from the sensor. 
 

Interchangeable covers 

The contact comes from the factory assembled with a white cover, but included are option brown 
covers. To change the cover simply slide the front cover to disengage it from the sensor then 
remove. Replace with the brown cover ensuring the Top (as marked on the inside of the cover) 
points away from the battery. You should hear a click when the cover engages and disengages 
from the sensor. You do not need to replace the back plastic because once mounted the back is 
not visible. 
To replace the magnet cover you will need to gently pry the white cover off with a flat head screw 
driver and snap the brown cover in place. 
         

 
 
 
 
 