 Audio Detector Installation Instructions 

 

Product Overview 

 

Z-Wave+

™ enabled device which provides fire and CO (carbon monoxide) 

status 

 

Transmits Fire and CO alarm status 

 

Reports tamper condition when cover is open 

 

Product Specifications 

 

For indoor use only 

 

Detection Distance: 6 inches max 

 

Operating frequency: 908.42 MHz 

 

Operating temperature: 0° 

– 49°C, 32° – 120°F (ambient temperature) 

 

Operating humidity 5-95% non-condensing 

 

Battery type required: 3V Lithium CR123A 

 

Battery life approximately 5 years

 

 
 
Network Inclusion 

The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network both the 
sensor and the network controller must be in inclusion mode at the same time. 

Refer to the instructions 

provided by the manufacturer of your specific controller for details on initiating the controller’s inclusion mode.

  

 

1) 

Verify that the Z-wave Plus controller you are using is compatible with the FireFighter

tm

2) 

Either mount or move the FireFighter

tm

 sensor as close as possible to the location the sensor will 

remain. See installation section below. 

3) 

Put your Z-wave Plus Controller into add (inclusion) mode.  

4) 

Open the FireFighter

tm

 case and press the learn button on the device for one second. If the LED 

starts blinking continually, the sensor has not been added.  Repeat steps 3 and 4. 
 

Network Exclusion 

1) 

Any sensor can be removed from any Z-Wave Plus controller. Follow the directions to put your Z-
Wave Plus Controller into exclusion mode. 

2) 

Open the FireFighter

tm

 case and press the learn button on the device for one second. If 

successfully removed from the Z-Wave Plus network, the devices Green LED should blink slowly 
continuously.  

 

 

 

 

 

 

 

Содержание firefighter

Страница 1: ...r to the instructions provided by the manufacturer of your specific controller for details on initiating the controller s inclusion mode 1 Verify that the Z wave Plus controller you are using is compatible with the FireFightertm 2 Either mount or move the FireFightertm sensor as close as possible to the location the sensor will remain See installation section below 3 Put your Z wave Plus Controlle...

Страница 2: ...larm detection the device can detect the presence of a carbon monoxide alarm By default the sensor is not guaranteed to detect a CO alarm The device can be configured to more reliably detect a CO alarm in exchange for a reduced battery life This mode can be changed by holding down the tamper switch and learn button for 10 seconds The device should then be reset remove battery and replace in order ...

Страница 3: ...lease test the unit once per week to ensure proper functionality Installation The package contains the following 1 FireFighter Sensor 1 Sensor Mounting Bracket 2 Screws for Sensor Mounting Bracket 1 Adhesive tape for Sensor Mounting Bracket STEP ONE Identify Location for Sensor Determine the location of the smoke or CO detector that you require the FireFighter to detect Note that the sensor must b...

Страница 4: ...it is pointed toward the smoke detector STEP TWO Mount the sensors mounting plate to a clean dry surface with the adheasive tape and or the screws provided Note the arrow should point toward the device that the FireFighter is intended to detect Slide the Firefighter onto the mounting plate Smoke Detector Microphone 6 max FireFighter Sensor ...

Страница 5: ...ntended for software engineers working on Z Wave Plus controllers and home automation enthusiasts to integrate the Z Wave Plus FireFighter into their system Device Classes Generic Device Class GENERIC_TYPE_SENSOR_ NOTIFICATION Specific Device Class SPECIFIC_TYPE_NOTIFICAT ION_SENSOR Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO v2 COMMAND_CLASS_VERSION v2 COMMAND_CLASS_MANUFACTURER_SPECIFIC v2 COMM...

Страница 6: ...tting Low Replace Battery Now 0x0B Battery Needs Replacing Z Wave Plus Command Class Basic For backwards compatibility with older Z Wave Plus Controllers the Basic Command Class is supported in the following manner If either a smoke alarm or a CO alarm is detected the lifeline nodes will receive an unsolicited Basic Report of 0xFF When no more smoke or CO alarm sound detected the lifeline nodes wi...

Страница 7: ... hour and 1 week with interval steps of 200 seconds The sensor will also send a wakeup notification whenever the case is closed The FireFighter detector does not detect the presence of smoke heat or fire directly It relies solely on the presence of an audio alarm signal generated by an existing smoke or fire detector in proximity to the Firefighter detector to make such a determination The FireFig...

Страница 8: ...a norme d Industrie Canada exempts de licence RSS Son fonctionnement est soumis aux deux conditions suivantes 1 c et appareil ne peut pas provoquer d interférences et 2 c et appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif FCC ID XQC FFZ5 IC 9863B FFZ5 Warranty Ecolink Intelligent Technology Inc warrants that for a ...

Отзывы: