TM
FFZB1-ECO
AUDIO DETECTOR
patent pending
Installation Manual & Users Guide
SPECIFICATIONS
Frequency: 2.4GHz
Operating Temperature: 32°-120°F (0°-49°C)
Battery: One 3Vdc lithium CR123A (1550 mAh)
Operating Humidity: 5-95% RH non condensing
Battery life: 4 years
Supervisory signal interval: 27 min(approx.)
Detection distance: 6 in max
Maximum current draw: 135mA during transmission
3
rd
Party Certifications: FCC, IC, ETL
OPERATION
The FireFighter™ sensor is designed to listen to the alarm sounder of any smoke detector. Once confirmed as an
alarm, it will transmit a signal to the alarm control panel which if connected to a central monitoring station, will
dispatch the fire department.
WARNING: This audio detector is intended only for use with smoke detectors but it does not detect the presence of
smoke, heat, or fire directly.
ATTENTION: Ce détecteur audio est uniquement destiné à une utilisation avec des détecteurs de fumée, mais il ne
détecte pas la présence de fumée, la chaleur ou le feu directement.
ENROLLING
(
see
IMAGE: 1)
To enroll the sensor, set your panel into program mode. Refer to your specific alarm panel instruction manual for
details on these menus. Once in program mode, place the battery into the sensor and follow the instructions that
appear on the panel. When “Trip to Pair” appears on the screen, press the tamper button to complete the
enrollment process. See LED section below for more information on initial power up behavior.
NOTE: For best results, pair the device to your panel before installation.
MOUNTING
(
see
IMAGE: 2 & 3)
Included with this device is a mounting bracket, hardware and double sided tape. To ensure proper operation
ensure the side of the device with the small holes is directly facing the sounder holes on the smoke detector.
Secure the mounting bracket to the wall or ceiling using the two mounting screws and double sided tape
provided, then secure the audio detector to the mounting bracket using the small screw provided. The
FireFighter™ must be mounting within 6 inches of the detector for optimal operation.
WARNING: Non-interconnected smoke detectors require an audio detector by each smoke detector sounder.
ATTENTION: Detecteurs de fumée non interconnectés nécessitent un détecteur audio par chaque sondeur
détecteur de fumée.
This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72,
(National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper
installation, operation, testing, maintenance, evacuation planning, and repair service is to be provided with this
equipment. Warning: Owner’s instruction notice: ’Not to be removed by anyone except occupant’.
Cet équipement doit être installé conformément au chapitre 2 du National Fire Alarm Code, ANSI / NFPA 72 (
National Fire Protection Association , Batterymarch Park , Quincy , MA 02269 ) . Les informations imprimées
décrivant l'installation , le fonctionnement , les tests , la maintenance , la planification de l'évacuation , et le service
de réparation doit être fournie avec cet équipement . Attention: l'instruction d'un préavis de propriétaire : “Ne pas
être éliminé par personne, sauf l'occupant”