10
Technical data
Data
Value Unit
Supply voltage (options)
50/ 60 Hz
Supply voltage (options)
230 /115 V AC
Power
25 W
Degree of protection
II
Fine-wire fuse
5 x 20 mm
Internal protection 125 mA for
230 V
Internal protection 250 mA for
115 V
Degree of protection, housing
32 IP
Metering time adjustment (increments of 0.01 sec.)
0,01 to 99,99 sec.
Pre spraying time adjustment
(increments of 0.01 sec.)
0,00 to 99,99 sec.
After spraying time adjustment
(increments of 0.01 sec.)
0,00 to 99,99 sec.
Compressed air supply *
0,45 (4,5) – 0,6 (6) MPa (bar)
Spray air pressure range
0 - 0,38 (3,8) MPa (bar)
Start signal floating contact or transistor (max.)
24 / 5 V / mA
Reserve signal
(Capacitive key with make contact function)
pnp
Empty signal
(Capacitive key with make contact function)
pnp
Collective fault signal , Potential free (max.)
24 / 2 V AC/DC/A
‘Finished’
signal , Potential free (max.)
24 / 50 V AC/DC/mA
Dimensions (W x H x D)
300 x 114 x 200 mm
Housing material
Polystyrene,
acrylic paint finish
Weight
2,7 kg
*
The compressed air must be clean, dry and free of oil. Divergence from the input
pressure in either direction (up or down) may result in impairment of function.
CAUTION!
Compressed air must be clean, dry and oil-free. Exceeding or underflow of
the supply pressure can impair the function.
Technical data
31
417101439 Rev. 2-09.2019