417101726_Ecoplus_PCB.docx
- 30 -
Rev. 02-02.2012
4.2.3
Configuration
CONFIGURATION
FUNCTIONS
FLUSHING?
NO
RINSE AID
METERING? NO
RESTORE
DEFAULT? NO
METERING ENABLE
EXTERNAL? YES
USE RINSE
TEMP? NO
PREMETERING
EXTERNAL? NO
MESSAGE LANGUAGE
ENGLISH
ARE YOU SURE ?
NO
METERING
SOLID
DETERGENT
SEL
DEVICE MODE
V VT
VX
RINSE PUMP MODE
CONT
This question appears
only, if there was a
change of the device type.
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
NEDERLANDS
ESPAÑIOL
CONT
TIME
SOLID
POWDER
LIQUID
ARE YOU SURE ?
NO
This question
appears only, if there
was an activation of
restore default.
SEL
3RD PROD.
METERING? NO
SMALL
STANDARD
DISHWASHER
TYPE: STANDARD
OVERSHOOT
PROTECTION: OFF
STANDARD
Controller works between 90% … 100%
(Controller interval time: 10s)
SMALL
Controller works between 80% … 100%
(Controller interval time: 20s)
OVERSHOOT PROTECTION
Interval time: 20s. When conductivity is lower 80/90%
the output is active in a pulse/pause - time:
e. g.:
”OFF“: 20s ON, 0s OFF (= deactivated)
”10%“: 19s ON, 1s OFF
“50”: 11s ON, 9s OFF
“100%“: 1s ON, 19s OFF
ZERO CALIBRATION AUTO
This function should be used in high- and changing
TDS water areas. If the auto zero calibration mode
is selected, an automatic zero calibration of the
water conductivity takes place following each filling
process of the d.w.
Only available in CONDUCT. mode when
PREMETERING/METERING EXTERNAL activated.
BACK
Programming Structure
Programming Structure
ECOPLUS (complete)
ECOPLUS (complete)
Software v2.00
Issue: 2007-19
V VT VX
P PT
PX
L LT
LX
To proceed from one menu to the next press
NEXT
NEXT
button.
Back to the starting level.
Press this button to proceed to a submenu,
or to scroll within a menu.
To increase a value within a menu.
To decrease a value within a menu.
Only visible if the corresponding function is activated.
Only visible with Add-On-Board.
SEL
( )
FLUSHING:
At Standard units (not „T“ or „X“) this time is fix
5 sec. and not adjustable
ZERO.CALIBRATION
AUTO? NO
DET. DOS. MODE
CONDUCT
CONDUCT.
TIME
DET.DOS.MODE
In the time controlled mode, the solenoid valve for
fresh water supply opens, as soon as the
corresponding enable signal is applied. The preset
value determines the time, for how long the solenoid
valve for fresh water supply is activated.
Only with Add-On Board
P/N 32355202
Legend:
Basic
“T” or “X”-Version
+
Содержание Ecoplus-PCB
Страница 14: ...417101726_Ecoplus_PCB docx 14 Rev 02 02 2012 6 Anschlusspl ne 6 1 Ecoplus V 6 2 Ecoplus VXRi...
Страница 15: ...417101726_Ecoplus_PCB docx 15 Rev 02 02 2012 6 3 Ecoplus VXN 6 4 Ecoplus P...
Страница 16: ...417101726_Ecoplus_PCB docx 16 Rev 02 02 2012 6 5 Ecoplus PXRi 6 6 Ecoplus PXN...
Страница 33: ...417101726_Ecoplus_PCB docx 33 Rev 02 02 2012 6 Connection Diagrams 6 1 Ecoplus V 6 2 Ecoplus VXRi...
Страница 34: ...417101726_Ecoplus_PCB docx 34 Rev 02 02 2012 6 3 Ecoplus VXN 6 4 Ecoplus P...
Страница 35: ...417101726_Ecoplus_PCB docx 35 Rev 02 02 2012 6 5 Ecoplus PXRi 6 6 Ecoplus PXN...