7.9.4.1 Incorrect [Access code]
The activated
[Access code]
is indicated by a closed padlock symbol on the operating
display.
Fig. 49: Incorrect password entry
1.
When attempting to open the
[Call up Main menu]
:
with the closed lock symbol the
[Access code]
query is started
2.
Pressing the button results in exiting the input for the
[Access code]
.
ð
Screen changes back to the operating screen.
3.
After entering the
[Access code]
press the
[Next]
button.
ð
If the
[Access code]
is incorrect, the screen changes:
‘Incorrect access code!’
If the password is correct, the screen changes back to the operating screen
4.
Select the button.
ð
The screen
‘Incorrect access code!’
is closed and a new query appears after the
correct
[Access code]
.
This process can be repeated any number of times, or cancelled as described
under position 2.
7.9.4.2 What can I do if I forget the access code?
What to do if you forget the access code
Reset the password:
If you forget the access code, you can contact Ecolab Service to request an
access code with which to “unlock” the pump and set a new code.
IMPORTANT:
–
When you contact Ecolab, ensure that you have the pump production code
(see type plate) to hand and note down the current date displayed on the
pump (at the lower right of the display).
–
The code provided by Ecolab is valid only for 24 hours.
This means that you must enter the code on the day it is provided by
Ecolab. The pump will accept the code only on this date.
Control / software
90
Rev. 2-05.2018