background image

S

MART

Z

ONE

ecojay

P

O

W
E

R

D

A

M

P

E

R

 1

24V
24C

Z1-PO

Z1-PC

RC
RH

COM

W2

O/B

Y1
Y2

G

E

Q

U

IP

M

E

N

T

REMOVE TO SEPARATE 
RC & RH TERMINALS

COM

Z

O

N

E

 1

 S

T

A

T

R

EC

Y
G

O/B

W

Z

O

N

E

 2

 S

T

A

T

R
C
Y
G

O/B

W

D

A

M

P

E

R

 2

Z2-PO

Z2-PC

COM

C

S

M

A

R

T

 L

IN

K

1

GND

2

S

A

 S

E

N

S

O

R

SA1
SA2

W1

EH

ecojay

S

MART

Z

ONE

Z

O

N

E

 3

 S

T

A

T

R
C
Y
G

O/B

W

Z

O

N

E

 4

 S

T

A

T

 o

F

A

R
C
Y
G

O/B

W

D

A

M

P

E

R

 3

Z3-PO

Z3-PC

COM

D

A

M

P

E

R

 4

Z4-PO

Z4-PC

COM

FRESH AIR

S

MART

Z

ONE

4X

ZS4X 

2.0

8E

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

THERMOSTATS:

 

HEAT PUMP

 OR 

GAS/ELECTRIC

EASY-TO-READ 

DISPLAY

LEDs SHOW

HEAT & COOL 

CALLS

(NO VOLTMETER 

REQUIRED) 

SCREWLESS

WIRING TERMINALS

FRESH AIR CONTROL

(4X ONLY)

SIMPLE SETUP AND

CONFIGURATION

EQUIPMENT:

GAS/ELECTRIC or

HEAT PUMP 

(Inc. DUAL FUEL)

2-STAGE Cooling

3-STAGE Heating

SUPPLY AIR TEMP 

SENSOR INCLUDED

EXPANDABLE

TO 20 ZONES

(4X ONLY)

DAMPERS:

2-WIRE or 3-WIRE

LEDs SHOW

POSITION 

RED = CLOSED

GREEN = OPEN

INSTALLATION & 

OPERATION

eco

jay

MADE IN THE USA

VERSION 8E 

FIRMWARE

TM

PART # ZS4X-2.0 (4-ZONE) PICTURED

PART # ZS2X-2.0 (2-ZONE) AVAILABLE

Содержание SmartZone ZS2X-2.0

Страница 1: ...ONE 4X ZS4X 2 0 8E HI TEMP LO TEMP SUPPLY PURGE DELAY ECO THERMOSTATS HEAT PUMP OR GAS ELECTRIC EASY TO READ DISPLAY LEDs SHOW HEAT COOL CALLS NO VOLTMETER REQUIRED SCREWLESS WIRING TERMINALS FRESH AI...

Страница 2: ...STAGE HEAT OR REVERSING VALVE ORANGE 10 AMP 24VAC CONTACT RATING 40VA POWER CLOSE SPRING OPEN DAMPERS 10VA POWER OPEN SPRING CLOSE DAMPERS 10VA POWER OPEN POWER CLOSE DAMPERS 3VA LABEL DESCRIPTION LE...

Страница 3: ...DED BY ANY ADDITIONAL PRESSURE RELIEF q REFER TO DUCT DESIGN BYPASS PAGE 3 4 q CALCULATE MINIMUM 24VAC TRANSFORMER VA CAPACITY PAGE 5 q CHECK PRIMARY AND SECONDARY VOLTAGE FOR ZONING TRANSFORMER MAKE...

Страница 4: ...E CFM CFM ROUND CFM CHART BYPASS PRESSURE RELIEF BYPASS SIZING SELECT A DAMPER SIZE WITH A MAX CFM GREATER THAN THE CFM NEEDED TO BYPASS USE THE FORMULA BELOW TO CALCULATE CFM NEEDED TO BYPASS AND THE...

Страница 5: ...E SPEED EQUIPMENT AVOID CREATING MORE THAN THREE ZONES WITH NO ZONE SMALLER THAN 20 OF THE TOTAL EQUIPMENT CFM CAPACITY RETURN AIR UNDERSIZED RETURN AIR DUCTS REGISTERS CAN RESULT IN PROBLEMS DUE TO I...

Страница 6: ...DETAILS IN ZONING GUIDE ENERGIZES FAN AFTER 90 SECOND DELAY WITH HEATING 2ND STAGE ACTIVE NORMAL AUX HEAT COMPRESSOR ELECTRIC HEAT STRIPS REVERSE VALVE ON IN COOLING EQUIPMENT GAS ELECTRIC STANDARD HE...

Страница 7: ...TRIC OR DUAL FUEL AFTER COIL BEFORE BLOWER SAS INCLUDED ALWAYS TO THE LEFT EXCEPT FOR 5 THROUGH 20 ZONES DETAILS PAGE 14 ENERGIZES FAN IMMEDIATELY WITH HEATING 2ND STAGE ENERGIZES ONLY IF MORE THAN ON...

Страница 8: ...ED NOTE ALWAYS DISCONNECT POWER TO SMARTZONE WHILE MAKING ANY WIRING CHANGES DO NOT USE EQUIPMENT TRANSFORMER 24 VAC COMMON TRANSFORMER PRIMARY INSTALLATION DO NOT CONNECT POWER UNTIL ALL WIRING IS CO...

Страница 9: ...G 24VAC R HEATING EH O B PC PO COM POWER OPEN POWER CLOSE 24 VAC 2 3 VA SPRING OPEN POWER CLOSE 24 VAC 6 10 VA DAMPERS SUPPLY TEMP EQUIPMENT REQUIRES SEPARATE TRANSFORMERS FOR HEAT AND COOL NOTE RELAY...

Страница 10: ...2 STAGE GAS ELECTRIC H2 2 STAGE HEAT PUMP 4 HI TEMP LO TEMP SUPPLY PURGE DELAY ECO ZONE PRESS RELEASE THE UP ARROW BUTTON WHEN THE DISPLAY IS SHOWING SUPPLY TEMPERATURE THE HI TEMP INDICATOR WILL FLA...

Страница 11: ...LS OTHER ZONES WILL ONLY OPEN AND CLOSE DAMPERS AS NEEDED FLASH ON SE SETTING CHANGES STORED IN MEMORY THIS WILL SHOW UP AFTER ADJUSTING ANY SETTING INCLUDING STAT TYPE LIMIT TEMPERATURES AND FRESH AI...

Страница 12: ...E SMARTZONE SYSTEM WILL BE LOCKED INTO EMERGENCY HEAT THE COMPRESSOR WILL NOT ENERGIZE AND ONLY HEATING CALLS WILL BE RECOGNIZED FROM ANY ZONE OTHER THAN ZONE 1 ONLY W1 EH AND G WILL BE ALLOWED TO ENE...

Страница 13: ...10 2ND STAGE WILL NOT RE ENERGIZE UNTIL AFTER 3 MINUTES OFF TIME IF SUPPLY TEMP IS WARMER THAN HI TEMP SEE ADJUST LIMITS FAN WILL RUN BUT W1 WILL DE ENERGIZE FOR 3 MINUTES AND UNTIL SUPPLY TEMP IS CO...

Страница 14: ...LAY ECO 2 3 PRESS TO SELECT THE OF MINUTES PER HOUR FOR FRESH AIR RUN TIME IN 5 MINUTE INCREMENTS PRESS STAT TYPE BUTTON TO SELECT ZONE 4 PRESS UP BUTTON TO SELECT FA PRESS STAT TYPE AGAIN 4 0 HI TEMP...

Страница 15: ...HE PRIMARY AND SECONDARY POLARITY MUST BE THE SAME ON ALL SMARTZONE 4X BOARDS 24VAC 24VAC FIRMWARE VERSION SHOWN ON DISPLAY AFTER RESET OR POWER UP CONNECT EQUIPMENT SAS ONLY TO MAIN ZONES 1 4 SMARTZO...

Страница 16: ...FAN SPEED WIRING POWER ETC ANY PROBLEM ASSOCIATED WITH THE EQUIPMENT A INCOMPATIBLE POWER STEALING NO COMMON B DEFECTIVE THERMOSTAT C WIRING DEFECT D STAT TYPE SETUP HEAT PUMP ONLY A ACTUATOR FAILURE...

Отзывы: