Ecojay SMartZone-4X Скачать руководство пользователя страница 1

 FIRMWARE VERSION SHOWN ON 

DISPLAY AFTER RESET OR POWER UP

S

MART

Z

ONE

-4X

FRESH AIR & ECONOMIZER GUIDE

CLOSED = ENABLED, OPEN = DISABLED

WHEN ZONE 4 IS CONFIGURED AS FRESH AIR, CONNECTING A SWITCH OR 

SENSOR (24VAC) TO THE ZONE 4 THERMOSTAT TERMINALS WILL ACTIVATE 

ADVANCED FRESH AIR FEATURES. 

ADVANCED FRESH AIR

Y = ECONOMIZER

G = DEMAND FRESH AIR

W = ONLY WITH EQUIPMENT

O

/

B

 = FRESH AIR OFF

FOR BASIC FRESH AIR: DO NOT CONNECT THESE TERMINALS.

FRESH AIR CONFIGURATION

4

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

FA

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

2

3

PRESS 

▲▼

 TO SELECT 

THE # OF MINUTES PER 

HOUR FOR FRESH AIR RUN 

TIME (IN 5 MINUTE 

INCREMENTS)

PRESS STAT TYPE BUTTON 

TO SELECT ZONE 4

PRESS UP

 BUTTON 

TO SELECT FA

PRESS STAT TYPE AGAIN

4

0

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

I5

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

5

PRESS STAT TYPE AGAIN 

(OR WAIT 5 SECONDS) TO 

STORE SETTINGS

1

SE

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

ADJUST SETTINGS

STAT

 TYPE

FA

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY ECO

BASIC FRESH AIR OPERATION

SMARTZONE-4X WILL AUTOMATICALLY ENERGIZE FAN (G) AND OPEN THE FRESH 

AIR DAMPER (ZONE 4) FOR A CONFIGURABLE  # MINUTES PER HOUR (FRESH AIR 

RUN TIME) FRESH AIR RUN-TIME IS ATTEMPTED DURING EQUIPMENT 

CALLS BUT WILL BE COMPLETED AT THE END OF THE HOUR 

AUTOMATICALLY TO SATISFY THE FRESH AIR RUN-TIME SET BY USER 

EVEN IF EQUIPMENT HAS NOT RUN

R

Y
G

O/B

W

C

Z

O

N

E

 1

 S

T

A

T

Z

O

N

E

 4

 S

T

A

T

FOR MORE INFORMATION 

ABOUT FRESH AIR SETUP SEE 

“SMARTZONE INSTALL  GUIDE” 

AVAILABLE AT ECOJAY.COM

VERSION 8E FIRMWARE ONLY

Y = ECONOMIZER / 

FREE

 

COOLING

(

SEE

 

BACK

 

OF

 

PAGE

 

FOR

 

DETAILS

)

G = DEMAND FRESH AIR / 

VENT

T

URN

 

ON

 

FRESH

 

AIR

 

MANUALLY

EQUIPMENT

 

G

 

WILL

 

ENERGIZE

 

AND

 

FRESH

 

AIR

 

DAMPER

 

WILL

 

OPEN

W = ONLY WITH EQUIPMENT

E

NERGIZE

 

THIS

 

TERMINAL

 

AND

 

FRESH

 

AIR

 

WILL

 ONLY 

RUN

 

WITH

 

EQUIPMENT

 

RUN

 

TIME

 (

EVEN

 

IF

 

MORE

 

MINUTES

 

HAVE

 

BEEN

 

SET

 

FOR

 

THE

 

HOUR

)

O

/

B

 = FRESH AIR OFF

F

RESH

 

AIR

 

IS

 

TOTALLY

 

DISABLED

AUTOMATIC

 # 

MINUTES

 

PER

 

HOUR

 

RUN

 

TIME

ECONOMIZER

 

MODE

AND

 

DEMAND

 

FRESH

 

AIR

 ALL WILL NOT RUN. 

eco

jay

BYPASS 

DUCT

EVAP.
COIL
(

COOLING

)

FURNACE 
(

HEATING

)

R

ETURN

 A

IR

BYPASS 

DAMPER

PC

P0

COM

ec

oj

ay

24

 v

ac

 

(2

V

A

)

POWER 
OPEN/CLOSE 
DAMPER

F

RE

SH

 AI

R

ecojay

D

A

M

P

E

R

 1

Z1-PO

Z1-PC

RC
RH

COM

W2

O/B

Y1
Y2

G

E

Q

U

IP

M

E

N

T

COM

D

A

M

P

E

R

 2

Z2-PO

Z2-PC

COM

S

M

A

R

T

 L

IN

K

1

GND

2

S

A

 S

E

N

S

O

R

SA1
SA2

W1

EH

ecojay

S

MART

Z

ONE

D

A

M

P

E

R

 3

Z3-PO

Z3-PC

COM

D

A

M

P

E

R

 4

Z4-PO

Z4-PC

COM

FRESH AIR

S

MART

Z

ONE

4X

ZS4X

 

2.0

ADJUST SETTINGS

STAT

 TYPE

8E

HI TEMP

LO TEMP

SUPPLY

PURGE

DELAY

ECO

P

O

W
E

R

24V
24C

R

EC

Y
G

O/B

W

Z

O

N

E

 2

 S

T

A

T

R
C
Y
G

O/B

W

C

Z

O

N

E

 3

 S

T

A

T

R
C
Y
G

O/B

W

Z

O

N

E

 4

 S

T

A

T

 /F

A

R
C
Y
G

O/B

W

Z

O

N

E

 1

 S

T

A

T

Z4-PO

COM

Z4-PC

D

A

M

P

E

R

 4

57.8

VENT
OFF

AUTO

F

REE

 C

OOL

 

O

FF

/A

UTO

SETPOINT

F

RESH

 A

IR

O

UTDOOR

 T

EMP

V

ENT

 

O

N

/O

FF

THERMOSTAT

.com

TAKE ADVANTAGE OF 
CAPABILITIES BUILT-IN 
SMARTZONE-4X WITH A 
FRESH AIR DAMPER AND 
ECONOMIZER “FRESH AIR” 
THERMOSTAT.
BY AUTOMATICALLY 
UTILIZING OUTSIDE AIR 
INSTEAD OF 
COMPRESSOR WHEN 
ECONOMIZER INPUT IS 
ENABLED, SAVE 
EQUIPMENT RUN TIME 
AND ENERGY. 

USING OUTSIDE 

AIR TEMPERATURE, 

THE FRESH AIR 

THERMOSTAT 

WILL ENABLE 

ECONOMIZER ON 

SMARTZONE-4X

NOTE: A HUMIDITY OR ENTHALPY 
SENSOR COULD ALSO BE USED 
TO ENABLE ECONOMIZER.

Отзывы: