Manufacturer reserves the right to change specifications or designs without notice.
10.2019
ESI (Ultra) Service Manual
14/68
TD≥C
TD<D
TD<D
TD≥B
Upper limit compressor
After 15 sec.
TD≥B
TD≥A
Upper limit compressor step = Current step
Normal operation
(Upper limit compressor step = Max. step)
2.2.3.3
Discharge temperature protection control
This discharge temperature (TD) protection control is used to protect the compressor internal
temperature against a malfunction or transient increase of discharge pipe temperature.
step: Decrease 2steps
Current step maintained
and
TD<D
Restart permission=ON
Symbol
EODA18H-2436/4860
Cooling
Heating
A
248
°
F (120
°
C)
230
°
F (110
°
C)
B
230
°
F (110
°
C)
212
°
F (100
°
C)
C
212
°
F (100
°
C)
194
°
F (90
°
C)
D
194
°
F (90
°
C)
176
°
F (80
°
C)
Discharge temperature abnormal standby
Compressor restarts