System Operation If Connected To Off Peak Electricity
•
There are no special settings for the off-peak connection. The system will run once the power
becomes available and the temperature in the tank drops below the set point of the tank thermistor.
If connecting the unit to off-peak, ensure that the off peak tariff provides a minimum of 2 hours
continuous power, as it can take at least 2 hours to fill the tank unit with hot water. If the ambient
temperature is lower than 10
◦
C, this can be longer.
•
If the unit is connected to off peak and consumption has been higher than usual, hot water might
not be available until the next power supply cycle.
•
Daily frequency and amount of hot water consumption may also affect the duration of the heating
cycle operation.
Select the electrical supply mode that best suits the customer’s hot water consumption. The type
of off peak connection may need to be changed if hot water supply is not maintained as required.
Figure 5: Outline of electrical system connections
How to connect power line
Please note:
Electrical installation should only be done by a licenced electrician.
•
Connect the power supply line to the terminal block.
Caution: Use Copper Wiring