Ecoair ECO15P Скачать руководство пользователя страница 20

ONE (1) YEAR LIMITED WARRANTY 

SAVE THIS WARRANTY INFORMATION 

EcoAir  guarantees  this  product  free  from  defects  in  materials  and 
workmanship for a period of one (1) year from the date of purchase, limited 
to parts only. 

Faults arising from a faulty installation is specifically excluded. 

This  unit  must  be  operated  under  conditions  as  recommended,  at  voltages 
indicated  on  the  unit.  Any  attempts  made  to  service  or  modify  the  unit  by 
unqualified  technician,  will  render  this  WARRANTY  VOID.  The  actual 
product may differ slightly from the illustration. This warranty is in addition to, 
and does not affect, your statutory rights.  

For  after  sales  needs,  please  visit  www.ecoair.org/service  or  email 
[email protected] or contact 0845 388 0007 

We  recommend  that  you  note  the  details  of  your  purchase  below  and  retain 
your original proof of purchase receipt with this manual. Keep these documents 
safe  in  the  event  of  a  warranty  claim.

Please  register  your  product  online  at 

www.ecoair.org. 

Date of purchase:     

 

 _____________________________ 

Purchased from (Dealer Name):   _____________________________ 

Retailer name:         

 

 _____________________________ 

Model number:      

 

 _____________________________ 

Serial number:       

 

 _____________________________

Date of installation: 

 

 _____________________________ 

Copyright Reserved 

C170 

Содержание ECO15P

Страница 1: ...r conditioner Model information can be found on the CE label Please register your product online at www ecoair org For your future convenience record the model information below ____________________________________ MODEL NUMBER ____________________________________ SERIAL NUMBER ____________________________________ PURCHASE DATE ...

Страница 2: ...peration of Control Panel 9 Self Diagnosis 12 Drainage 13 Maintenance 15 Fault Checklist 16 Order Form 17 Disposal When using this air conditioner in the European countries the follow information must be followed DISPOSAL Do not dispose this product as unsorted waste It is prohibited to dispose of this appliance in domestic household waste For disposal A Contact your local council for disposal B T...

Страница 3: ...onnected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN or GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened cor...

Страница 4: ...r rotary Sound Pressure Lp 50 52 57 dB A Sound Power Lw 58 60 65 dB A Refrigerant R410A 560g Fan speed 3 Timer 1 24 hours Working temperature Cooling 18 32o C Heating 7 25o C Exhaust pipe Ø 142x1500mm Net Weight 33 5 kgs Gross Weight 38 5 kgs Net Dimension WxHxD 422x825x443 mm Gross Dimension WxHxD 490x875x575 mm REMARK 1 Measuring condition for above is as per EN 14511 Cooling DB 35 C WB 24 C Hea...

Страница 5: ...AL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH APPLIANCE ELECTRICAL SAFETY FOR INDOOR USE ONLY SWITCH OFF AND UNPLUG WHEN NOT IN USE DO NOT USE IN HUMID OR WET ENVIRONMENTS FIG 3 DO NOT PULL THE UNIT ...

Страница 6: ...ing effectiveness Avoid opening doors frequently Keep curtains or blinds closed during the warmest part of the day Keep filters clean Once room has reached the desired conditions reduce temperature and ventilation setting Locate air conditioner where airflow is not obstructed to increase air flow Close any air grills windows or ducting to avoid cooled air escaping during use FIG 4 4 ...

Страница 7: ...se 11 PVC strip for filling the open window space 12 PVC strip for filling the open window space 13 PVC strip with hole for filling the open window space and with hole for connection to tie in 14 Outward adaptor for insertion over hose and into PVC strip or into hole in the wall window 15 Cover for outward adaptor 16 Remote control 17 Active carbon filter 18 Tube for continuous drainage FIG 7 5 FI...

Страница 8: ...and the other end with the outward adapter Feed the exhaust hose to the PVC strip as shown and slide window across so that PVC strip is held securely Note Take care to maintain protection against intruders 2 Using the adaptor FIG 9 FIG 10 Cut a 151mm diameter hole in the wall or window Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown When not i...

Страница 9: ...ir conditioner Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down Fig 11 12 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible 7 FIG 11 FIG 12 FIG 13 FIG 14 ...

Страница 10: ...Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fixer onto the filter frame 6 Re fit the filter frame inside the unit FIG 15 8 ...

Страница 11: ...iO2 UV light Ionizer button optional 17 Indicator for compressor 18 TiO2 UV light ionizer indicator optional 19 Sleep operation indicator 20 Timer operation indicator 21 Low ventilation indicator 22 Medium ventilation indicator 23 High ventilation indicator Turning ON OFF Adjust the louvers to desired angle and position Press ON OFF button the unit will start to work If the ambient temperature is ...

Страница 12: ...ose the fan speed you need high medium or low The sign of high low or medium fan will light on at the same time 2 If the unit is in AUTO mode it will choose the fan speed automatically according to the ambient temperature Setting timer 1 Press TIMER button to set the operating hours you desire 1 to 24 hours the sign of timer will light on The window will show the hour s you set as you press TIMER ...

Страница 13: ...ode Only available in Cooling or Heating mode Heating function This is optional only for cool heat model 1 When using Heat Pump the ambient warm air is recycled and use to heat the area where it is required The Exhaust Pipe must be fitted firmly to allow the cold air to be removed outside 2 Continuous drainage is compulsory while the unit is in heat mode Working ambient temperature range for heati...

Страница 14: ...ve the selected level the cooling will return to work 3 The heating will switch off if the ambient temperature is higher than the set temperature The fan keeps working on the set level As the ambient temperature drops below the selected level the heating will return to work 4 This machine is equipped with ANTI FROST function While using the heating function during low temperature sometimes the hea...

Страница 15: ...ioner and avoid moving it when full 2 Position a container a water tray for example underneath the drain hole 3 Remove the drain knob rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tray 5 Repeat until the unit is emptied 6 Replace the rubber plug and tighten the drain knob firmly 7 S...

Страница 16: ...OD 18mm FIG 22 Special caution for heating function While using the heating function please note 1 Install the exhaust pipe well in order to exhaust the cool air to outdoor Please refer to the instruction manual for installation method 2 Fix the drainage to be continuous one i e drain the water by water tube This is compulsory for use in heating mode 3 Working range for heating function is 7 to 25...

Страница 17: ...g the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40o C Dry thoroughly before replacing Note Never operate the unit without the filters End of season storage Drain any water in the unit then switch the unit to fan mode for a few hours to thoroughly dry the inside Clean or change th...

Страница 18: ...any people in the room y Is there something in the room producing lots of heat The machine seems to do nothing y Is the filter dusty contaminated y Is the air intake or output blocked up y Is the room temperature below your selected temperature Too noisy y Is the machine positioned unevenly so as to create vibration y Is the floor underneath the machine uneven The compressor doesn t run y Is so it...

Страница 19: ...our reference Fax Form To Us Fax 0845 388 9313 Mail Form To Us EcoAir Unit 7 Propeller Park 400 North Circular Road London NW10 0AB Order Today By Fax Post Or Via Online Tel 0845 388 0005 More Information http www ecoair org Model Number Description of Item Quantity Unit Price Amount Filters 15P 108 109 Real Filter Fixer 14 99 15P 110 Side Filter 14 99 15P 116 Filter Track 8 99 15P 806 Active Carb...

Страница 20: ... This warranty is in addition to and does not affect your statutory rights For after sales needs please visit www ecoair org service or email technical ecoair org or contact 0845 388 0007 We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual Keep these documents safe in the event of a warranty claim Please register your pr...