Страница 1: ...ES 1820SD WiFi X SERIES 2420SD WiFi _________ Register your air conditioner Model information can be found on the CE label I Please register your product online at www ecoair org For future convenience record the model information below Model Number Serial Number Split Air Conditioner 363 364 230112 a ...

Страница 2: ...by a person responsible for their safety Children should be supervised to ensure they are away from the appliance WEE EC2601UR 2018 EcoAir This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of...

Страница 3: ... Malfunction Troubleshooting 14 Installation Notice Installation dimension diagram 16 Tools for installation 17 Selection of installation location 17 Requirements for electrical connection 18 Installation Installation of indoor unit 19 22 Installation of outdoor unit 23 25 Vacuum pumping 26 Leakage detection 26 Post Installation Check 27 Test and operation Test operation 27 Attachment Install snow...

Страница 4: ... Do not connect via an extension lead or Multi socket plug Extension leads and Multi socket plugs do not guarantee the required safety of the appliance e g danger of overheating 16 Do not use the appliance without the air filter Clean or replace the air filter regularly 17 At the end of its working life dispose of the appliance responsibly in accordance with local regulations 18 Before cleaning or...

Страница 5: ...sition may be different from above graphics please refer to actual products OUTDOOR UNIT Actual product may be different from above graphics please refer to actual products 2018 EcoAir 4 Aux Button Horizontal Lauver Remote Controller Air Inlet Handle All rights reserved Air Inlet Panel Filter ...

Страница 6: ...in the room where there is wireless telephone fluorescent lamp When the air conditioner is not in use for a long time please remove batteries from the remote controller If there is no display on the remote control please replace batteries 2018 EcoAir REMOTE CONTROL DISPLAY SCREEN l14rn l MNMii 1 Q Se t temp ill Indoor a mbienttemp I I o Ou t do o r ambie nt temp I Turbo mode i Set fan speed FAN HI...

Страница 7: ...the FAN button to adjust the fan speed Press Swing button to adjust the swing angle Cool Mode Whenthe indicator on the remote shows yourunitwillbeonCool Mode You can press the _ or buttonto adjust or set thetemperature Press the FAN button to adjust the fan speed Press the Swing button to adjust swing angle Dry Mode The air conditioner will begin to operate at a low speed The dry indicator will sh...

Страница 8: ...tion Under Fan Dry and Auto modes this function is unavailable 7 Temp Button Press this button to see the indoor set temperature indoor ambient temperature on the indoor unit s display The setting on remote controller is selected circularly as below rno display _____ Q ___ QJ _ D ___ When selecting the II Q II the display will show the set temperature This will be displayed on both the indoor unit...

Страница 9: ...ess this button to set timer ON HOURS ON Press 11 _ 11 or II T II button to adjust timer setting time will change quickly if holding 11 _ 11 or II T II button Time setting range is 0 5 24hours Press this button again to confirm timer setting and the characters of HOUR ON OFF will stop flashing If the characters are flashing but you haven t pressed the timer button the timer setting status will qui...

Страница 10: ...on of TEMP and TIMER buttons Energy Saving Function Press TEMP and Timer button simultaneously in COOL mode to start energy saving function The remote controller will display SE Repeat the operation to quit the function Not all models have this function Combination of TEMP and TIMER buttons About 8 C Heating Function Press TEMP and TIMER simultaneously in HEAT mode to start 8 C Heating Function Th...

Страница 11: ...nd Maintenance Note Turn off the air conditioner and disconnect the power before cleaning to avoid personal injury by electric shock Do not wash the air conditioner with water to avoid personal injury by electric shock Do not use volatile liquids to clean the air conditioner CLEANING THE SURFACE OF THE INDOOR UNIT If the surface of your unit is dirty we recommend that you use a soft dry cloth to c...

Страница 12: ...ies making sure the position of the 11 11 polar and 11 11 polar are correct 3 Reinstall the cover of the battery compartment Signal Sender Battery Cover of battery compartment NOTE During operation point the remote control signal sender at the receiving window on the indoor unit The distance between signal sender and receiving window should be no more than 6m and there should be no obstacles betwe...

Страница 13: ...e water below 45 C to clean it and then put it in a shady and cool place to dry Install filter The filter should be cleaned every three months If there is a large amount of dust in the oper ating environment check and clean more frequently After removing the filter do not touch the fins to avoid injury Do not use fire or a hair dryer to dry the filter it can cause deformation 2018 EcoAir 12 All ri...

Страница 14: ...Check whether the drainage pipe is damaged Checks after use 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact a qualified engineer NOTICE FOR RECOVERY Many packing materials are recyclable materials Please dispose of them using an appropriate recycling method If you want to dispose of the ...

Страница 15: ...ce them No display when operating Check whether the remote controller ap remote controller pears to be damaged If yes replace it Take the remote controller closer to the in Fluorescent lamp in room door unit Turn off the fluorescent lamp and then try it again Air inlet or air outlet of indoor Eliminate obstacles unit is blocked Under heating mode indoor After reaching set temperature the indoor No...

Страница 16: ...indow good Set temperature is in proper range Adjust temperature to proper range Odours are Check the odour s source it Eliminate the odour source emitted might be coming from exter Clean the filter nal source Air conditioner Whether there s interference operates nor such as thunder wireless devic Disconnect power put back power and then turn on the unit again mally suddenly es etc Outdoor unit Du...

Страница 17: ...0 t5 J _ Cl c 0 ___ E 0 Q 0 LO c N 0 Cl m Q Q c Cl I c For illustration purposes only Space to the wall Drainage pipe 1 S c o I L H 11 ___ e o O 0 ri c e 0 b S e 16 1 Space to the obstruction All rights reserved cu E E I 0 en Q co Q co a Cl ...

Страница 18: ... and air outlet 2 Select a location where the condensation water can be dispersed easily and will not affect otherpeople 3 Select a location which is convenient to con nect the outdoor unit 4 Select a location which is out ofreach of children 5 The location should be able to withstand the weight of the indoor unit and won t increase the noise and vibration 6 The appliance mustbe installed 2 5m abo...

Страница 19: ...n accordance with national wiring regulations 10 Installation must be performed in accordance with local regulations and by a qualified electrician Earthing requirement 1 Split air conditioners are Class 1 electrical appliances It must be properly earthed with a special ized grounding device by a qualified electrician Please make sure it is always earthed effectively otherwise it may cause electri...

Страница 20: ...s loose please drill another fixing hole nearby Step three Drilling a hole for the communication cable and condensing hose 1 Choose the position of the piping hole according to the direction of the outlet pipe The position of the piping hole should be a little lower than the wall mounted frame shown below X SERIES 920 X SERIES 1220 X SERIES 1820 X SERIES 2420 2 Open a piping hole with the diameter...

Страница 21: ...e refrigerant and re sult to leaks and contamination of the refrigerant Hex nut diameter Tiqhteninq toraue N m Cl 6 Cl 9 52 Cl 12 Cl 16 Cl 19 indoor pipe 4 Adjust the torque force by referring to the above sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tighten the union nut with the torque wrench Step six install drain hose 1 Connect the drain hose t...

Страница 22: ...and then tighten the screw 5 Close the panel Note All wires of the indoor unit and outdoor unit should be connected by a qualified F GAS Engi neer If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself Step eight banding the pipes 1 Banding the connection pipe power cord and drain hose indoor and outdoor power cor 2 Res...

Страница 23: ... mounting frame 3 Stuff the gap between pipes and wall hole with a sealing gum 4 Fix the hole cover plate 5 Check if the indoor unit is installed firmly and close to the wall upper hook sealing gum lower hook of wall mounting frame Note Do not bend the drain hose too excessively this can cause blocking 2018 EcoAir 22 All rights reserved ...

Страница 24: ...door unit should be installed at least 2cm above the floor in order to install drain joints At least 2cm above the floor Step two install drain joint Only for cooling and heating unit 1 Connect the outdoor drain joint into the hole on the chassis as shown in the picture below 2 Connect the drain hose into the drain vent drain ven chassis Drain outdoor drain joint Step three fix outdoor unit 1 Plac...

Страница 25: ...e signal control wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws Note the wiring board is for reference purpose please refer to the actual unit handle 09K 12K 18K for some models blue black brown yellow blue broNr1 yellow green black Jelen N L POWER Indoor unit connection 18K 24K for some models f N 1 2 3 L N yellow blue black brown brown b...

Страница 26: ...rain from getting into the room Note The drain hose shouldn t be higher than the outlet pipe hole of the indoor unit th f i i ose wards The water outlet can t be placed in water in order to drain smoothly 2018 EcoAir X The water outlet can t be placed_ in water 25 __ Li shaped curve drain hos Slant the drain hose slightly dow nwards The drain hose can t be curved raised and fluctuant etc X The dra...

Страница 27: ... remains in 0 lMPa If the pres sure decreases there may be leakage liquid valve gas valve refrigerant charging vent 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent Leakage detection 1 With leakage detector Check if there is leakage with a leakage detector 2 With soap wat...

Страница 28: ...e specification It may cause malfunction or damage to the internal components Is there any obstruction in the air inlet and outlet It may cause the unit to insufficiently cool or heat The dust and sundries caused during installation are It may cause malfunction or damage the internal corn removed ponents The gas valve and liquid valve of the connection pipe It may cause the unit to insufficiently ...

Страница 29: ... guard Install in windward side Win ward side I The snow guard shall be wider than the air conditioner 2018 EcoAir Correct Snow guard Provide at field JIJOIID BlmIJ rr JD arm rr JII ITIJIJ EIJ ii rr s J ffH reg IIT Jlarm arm IC II E J ITIIIJ Height of base in consideration of snow More than 50cm Height of base in consideration of snow More than 50cm 28 seasonal Incorrect bdiil 0 0 0 IBl mIJ rr n a...

Страница 30: ...igerant charging amount on the basis of liquid pipe is Additional refrigerant charging amount prolonged length of liquid pipe x additional refrigerant charging amount per meter When the length of connection pipe is above Sm add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different Sheet 2 Additional refrigerant charging amoun...

Страница 31: ...e insulating pipe 4 Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on pipe union ipe pipe 2018 EcoAir 30 5 Expand the port Expand the port with an expander Note A is different according to the diameter please refer to the sheet below Outer diameter A mm mm Max Min 1 6 6 35 1 4 1 3 0 7 9 52 3 8 1 6 1 0 12 12 7 1 2 1 8 1 0 15 8 16 5 8 ...

Страница 32: ...y member of staff 8 Warranty provision will be free of charge and we will decide whether this will take the form of a repair or the replacement of the appliance Small appliances that can be reasonably transported or posted may need to be handed over or shipped to our customer service centre A purchase receipt must be present ed in each case Replaced parts pass into our ownership 9 Under no circums...

Отзывы: