SAFETY INSTRUCTIONS

1.

Make sure your battery has enough voltage

for the controller to

recognize the battery type before first installation.
2.The battery cable should be as short as possible to minimize loss.
3.The regulator is only suitable for lead-acid,lithium ions and
LiFePO4 battery.

4.

The charge regulator is only suitable for regulating solar modules.

Never connect another charging source to the charge regulator.

PRODUCT FEATURES

1.Build-in industrial micro controller.
2.Large LCD display,all adjustable parameter.
3. PWM charge management.
4.Build-in short-circuit protection,open-circuit protection,reverse
protection,over-load protection.

5.Dual mosfet Reverse current protection ,low heat production.

6.This control can work with 0V battery.

SYSTEM CONNECTION

1.Connect the battery to the charge regulator - plus and minus.
2.Connect the solar module to the regulator - plus and minus.
3. Connect the consumer to the charge regulator - plus and minus.

The reverse order applies when deinstalling!

An improper sequence order can damage the controller!

KEY FUNCTION

Function 1: when the battery voltage is normal, click the key
to turn the load on or off.
Function 2: press and hold the key for 2s to enter the menu.
On the menu where you need to change the setting, press
and hold the key for 2s to make the number blink, then click
to adjust the setting value, and then press and hold the key
for 2s to stop the number blinking, that is to say, the setting
is completed.

Function 3: long press the key for more than 10s until F01 is
displayed on the screen to restart the controller.
Function 4: press and hold the key for more than 20s until
F02 is displayed on the screen to restore the factory settings.

DISPLAY

NO.1

System voltage type selection interface. The factory

default battery voltage type is 12V, i.e. the interface is

displayed as u12v. If 24V is needed, it should be set

as u24v.

Setting method: long press for more than 2S until the

number flashes, then short press for adjustment, and

then long press for 2S until the number no longer

flashes after adjustment.

NO.2

Battery type

B01=General lead-acid(default)

B02=3S X 3.7V 11.1V lithium ion Battery

B03=4S X 3.2V 12.8V LiFePO4 Battery

B04=AGM / B05=GEL / B06=Flooded

Advise:choose B01 if you don

t know your lead-acid battery

type.

B01-B03 has 2-stage charging process .

B04-B06 has multi-stage charging process.

Setting:hold left key until number flash,click

+/-

to adjust,and

hold left key again until number stop flashing ,the setting is

saved.

NO.3

Load output timer control

24H

-output turn on all the time.

0H

-output turn on only during Dusk to Dawn(D2D).

1~23H

-output turn on after sunset and turn off after

1~23H.

Attn

no matter which is selected ,output will turn off

when battery is in a LVD condition.

Setting method:same as above one.

NO.4

controller

s body temperature display.if the controller gets

too hot during running ,it will automatic shut down and wait

for the temperature to drop to normal level ,and then it will

work again.

NO.5

Charging ampere display.(only for some model)

NO.6

Discharging ampere display.(only for some model)

NO.7

Charge voltage setting

only for B01,B02,B03

Different battery types have different maximum charging

voltage. Consult your battery supplier for more

information.Default setting is recommended.The setting is the

same as above

.

NO.8

Low voltage re-connect

LVR) setting

When a low voltage disconnect happens,the controller will

wait until the voltage raise more then this voltage,then it will

re-connect the load again.

Default setting is recommended.The setting is the same as

above

.

NO.9

Low voltage disconnect (LVD)setting.

When battery voltage is lower than this voltage,the controller

will cut off the output automatically .Default setting is

recommended.The setting is the same as above

.

NO.10

D2D trigger value(solar panel voltage)

When the work mode is D2D or Timer,the controller will

detect the solar panel voltage to decide whether its day or

night,so to decide to enable load output or not.the higher this

value is,the earlier it enables the load output.

Default setting is recommended.The setting is the same as

above

.

NO.11

D2D trigger delay value(Second)

When the controller detect the solar panel voltage is lower

than trigger value,it will delay for 10S and detect again to

make sure night falls, then enable the load output.some car

light or thunder lighting will confuse the controller and make it

think its daytime,using this delay can prevent interference.

Default setting is recommended.The setting is the same as

above

.

NO.12

Short-circuit protection setting.(only for some model)

Some inductive or capacitive consumer will trigger the

short-circuit protection during start up.therefore,you can

disable the SC-protection manually.

SC.F=OFF, SC.n=ON.the default is ON.

Default setting is recommended.The setting is the same as

above

.

NO.13

PWM charging enable(only for B01,B02,B03)

PWM could generate noise and interference which will trigger

a high voltage protection in a Li-Battery BMS

system.Therefore,to avoid this happen,you can choose to

disable the PWM charging.The controller will charge the

battery until Setting voltage(Menu NO.3),then it will fully stop

charging,when battery voltage drop ,it will re-charge again.

P.oN=PWM ON. P.oF=PWM OFF.

Default setting is P.oN. The setting is the same as above

.

NO.14

Output mode control.

Normally a LED light connected to the output terminal will

work only after sunset,therefore,LC1 can be selected.But some

load equipment requires to work only after sunrise,for

example,a camera or a pump.therefore ,you can choose LC2.

LC1 and LC2 are logically opposite on D2D control.

If you have set a timer(1-23H)control,for example 16H,but in

reality the night /day is only 12Hour.LC1/2 means output work

only 12H(any sunset or sunrise will stop the countdown) ,but

LC3/LC4 will work 16H(ignore any sunset or sunrise and

countdown until setting hours)

Default setting is LC1. The setting is the same as above

.

UNUSUAL DISPLAY

Battery low voltage warning .

To prevent damage of the battery, Output automatic

disconnect when battery voltage drop below LVD voltage and

automatic re-connect if raise above LVR voltage.

Press button to ignore for one time and force to work again.

Battery high voltage warning .

To prevent damage of the load equipment , Output automatic

disconnect when battery voltage raise above HVD voltage and

automatic re-connect if drop below HVR voltage.

Press button to ignore for one time and force to work again.

Output over current warning.(only for some model)

Load current exceed rated current.if it does not resume within

60 seconds,it will turn into E04 warning.

Press button to ignore for one time and force to work again.

Output short-circuit warning.(only for some model)

Output automatic disable when there is a short-circuit and will

resume after 10 seconds.

Press button to ignore for one time and force to work again.

High temperature warning .

when the temperature of the controller exceeds 80

, it will

enter stand-by mode and stop charging or discharging until

the temperature falls to 70

.

Press button to ignore for one time and force to work again.

PV over-voltage warning .

In order to protect the internal circuit,Charging automatic stop

when PV voltage exceed 50V and automatic recover when

voltage drop below 45V.(for 12V/24V system)

FAQ

Q:why the controller is not showing charging when I connect the solar panel?

A:please carefully check the solar panel wires are connected correctly,and there

is no reverse.the PV voltage should be higher than the voltage of the battery,any

sewage or shadow on the PV will cause the voltage drop.please use a 18v PV to

charge a 12V battery under normal circumstances.

Q:why is my charging current very small?

A:use more solar panel and stronger sun light will increase the charging

current,otherwise,using the wrong PV voltage or sewage and shadow on the PV

will reduce the charging current.in addition,when the battery voltage is high it

will enter float charging mode,also the charging current will become smaller.

Q:why my consumer is off?

It could be wrong working mode,like setting the work mode to D2D,but you are

asking why my consumer is off during the daytime.or battery is not enough and

a low-voltage disconnect has happened.or your consumer is broken,to check

that ,you can directly connect your consumer to the battery to see if it is

working,please carefully check the wires and so.

Q:the solar power stored is not enough to supply the consumer

A:If the power generated by the solar panel is less than the consumer used,the

consumer will have to get the power from the battery storage.and day by day,it

will cause a LVD finally at some moment.please use more solar panel and add

more battery capacity to prevent cloudy or rainy day,or you can reduce the watt

of the consumer or working time to balance the system.

Q

:why my battery runs out of power very quickly after it is fully charged?

A:your battery could have been used for a very long time,and after few hundred

of cycling, its dying.a dying battery will not have the capacity to keep the

electricity.run a simple test like this,when your charge your battery ,the voltage

raise very quickly ,and when you discharge it again,it drops very quickly,this

means you should change your battery.

TECHNICAL PARAMETER

System Voltage

12V/24Vauto

48V

MAX.PV input

<50V

<100V

Rated current

10A

20A

30A

10A

20A

30A

USB output

5V/2A

Charge control

PWM

Standby lost

<15mA@12V

<10mA@LVD

Working temp.

-20~+60

Size/Weight

138*85*30mm /150g

VOLTAGE PARAMETER

Battery

type

B01

B02

B03

B04

B05

B06

General

Lead acid

Li- ion

LIFePO4

sealed

GEL

Flooded

HVD

16V

16V

16V

16V

16V

16V

HVR

15V

15V

15V

15V

15V

15V

Bulk(Absorption)

13.7V

12.3V

14.0V

14.4V

14.2V

14.6V

Equalize

-

-

-

14.6V

-

14.8V

Float

13.7V

12.3V

14.0V

13.7V

13.7V

13.7V

Charge return

13V

12V

13V

13V

13V

13V

LVR

12.0V

10.5V

12.0V

12.6V

12.6V

12.6V

LVD

10.7V

9.5V

11.2V

10.7V

10.7V

10.7V

*all voltage X2 ,X4 while using 24V /48V system.
*Product specifications are subject to change without prior notice.

Содержание Solar Power Controller

Страница 1: ...ion over load protection 5 Dual mosfet Reverse current protection low heat production 6 This control can work with 0V battery SYSTEM CONNECTION 1 Connect the battery to the charge regulator plus and minus 2 Connect the solar module to the regulator plus and minus 3 Connect the consumer to the charge regulator plus and minus The reverse order applies when deinstalling An improper sequence order can...

Страница 2: ... has 2 stage charging process B04 B06 has multi stage charging process Setting hold left key until number flash click to adjust and hold left key again until number stop flashing the setting is saved NO 3 Load output timer control 24H output turn on all the time 0H output turn on only during Dusk to Dawn D2D 1 23H output turn on after sunset and turn off after 1 23H Attn no matter which is selecte...

Страница 3: ...nerate noise and interference which will trigger a high voltage protection in a Li Battery BMS system Therefore to avoid this happen you can choose to disable the PWM charging The controller will charge the battery until Setting voltage Menu NO 3 then it will fully stop charging when battery voltage drop it will re charge again P oN PWM ON P oF PWM OFF Default setting is P oN The setting is the sa...

Страница 4: ... or your consumer is broken to check that you can directly connect your consumer to the battery to see if it is working please carefully check the wires and so Q the solar power stored is not enough to supply the consumer A If the power generated by the solar panel is less than the consumer used the consumer will have to get the power from the battery storage and day by day it will cause a LVD fin...

Отзывы: