Overall Size:  Height (to hob)                      910mm 

Width (standard models)    1000mm 

Depth (to towel rail)             720mm 

Flue  6”  (150mm)  and  central  to  the  cooker,  but  centre  line  120mm  from  the  rear 

surface 

 

 
 

Hotplates:      340mm diameter x 2 with centre 

 

 
 

2 Ovens: 

Height 

280mm 

 

Depth 

 

Width 

525mm 

 

355mm 

 

 

Installation Instructions

 

 

When installing these appliances, all local regulations, including those referring to national & 
European Standards need to be complied with. 

This manual covers the ECO Range cooker appliance. 

The nominal space heating output is: 5kW 

The above appliances must be installed by the manufacturer or by a HETAS registered installer and the 
installation registered with the local council. 

 

Failure to comply with the above renders all guarantees and liabilities of the manufacturer null and void. 

The manufacturer will not guarantee or accept liability for any problem that arises unless, a HETAS 
installation commissioning certificate has been completed and a valid receipt or proof of purchase is 
presented from the approved supplier. 

 

The appliances should not be fitted closer than shown in the chart, from combustible materials, e.g. a 
wooden fire surround or stud wall. 

When fitted against a wall made of combustible material e.g.  a wooden stud wall with plasterboard, if the 
distance is less than the safe distance specified, extra non-combustible material of 75mm (min.) should be 
fitted behind the stove. When fitted inside a masonry or similar non-flammable material recess, e.g., 
fireplace opening, there is no minimum distance; the gaps are only an aesthetic consideration. 

Hearth

 

 

The cooker should stand on a non-combustible heath of minimum thickness 12mm (1/2”). This should 
extend a minimum 225mm (9”) in front of the cooker.  When the cooker is free-standing, the hearth should 
also extend a minimum of 150mm (6”) either side of the cooker. The hearth must be capable of taking the 
load of the appliance. Suitable measures, (e.g. a load distribution plate) should be taken if not, to ensure 
stability.

Содержание T3

Страница 1: ...Installation Instructions User Manual for the super efficient Log Wood burning Thornhill Turbo Technology Two Oven Boiler Cooker Please retain these instructions for future reference...

Страница 2: ...fficiency 81 9 Emissions CO concentration 13 Oxygen 0 16 Volume 2020 mg Nm Emissions Dust 13 Oxygen DEFRA UK Permitted 6 9g h Max Time above Ringelmann 2 10 43 mg Nm Actual 1 2g h Actual 0 0 Fuel Dry...

Страница 3: ...installation commissioning certificate has been completed and a valid receipt or proof of purchase is presented from the approved supplier The appliances should not be fitted closer than shown in the...

Страница 4: ...egative pressure in the room so they must have their own air vent to counter this Even when the air is taken directly from the outside using the manifold system a vent will be required for any extract...

Страница 5: ...d to help keep the combustion chamber temperature up for an efficient clean burn USER INSTRUCTIONS General operation The knob on the left is the air slide control out increases air to the cooker and i...

Страница 6: ...diagonally and finally 2 larger logs on top Light the firelighters open the air vent to maximum to the right and close the door to the first latch so there is an air gap around it Note firelighters ar...

Страница 7: ...n the form of briquettes Open the air vents and keep open till the stove cooker is very hot about 10 15 minutes b Use dry fuel load small amounts frequently where possible about 1 5kg is ideal don t l...

Страница 8: ...liance with the doors shut and look for telltale signs of excessive leakage Smoke stains above the firebox door smoke emitting around the door when running smoke stains where the vitreous enamel flue...

Страница 9: ...re the size of the balloon which equates to the height and diameter of your flue and the temperature of the air inside which equates to the quality of the chimney If the pilot want to go up he turns t...

Страница 10: ......

Страница 11: ...pe shield of the appliance Minimum distance to combustible material Back wall 20 cm Side wall 35 cm Recommended fuels Wood logs Emission of CO 0 16 vol Flue gas temperature 157 C Thermal output 10 3 k...

Страница 12: ...tion of direct air manifold Pipe is 110mm diameter Thornhill Turbo Technology is the patented clean burning engine used under licence in these cookers ECO Range Cookers 60 Wincheap Canterbury Kent CT4...

Отзывы: