E93.1801EN171 HWB installation manual
73
Water heater history
The history found in the information menu displays several history counters that keep track of the water heater
usage. The history cannot be erased and will continue for the burner controller life cycle. The following history data
is available:
(Sub) Menu item
Description
Successful Ignitions
Number of successful ignitions.
Failed Ignitions
Number of failed ignitions.
Flame Failures
Number of flame failures (loss of flame).
Operation Days
Number of days that the appliance is operational (powered ON).
CH Burner Hours
Number of hours that the appliance has burned for Central Heating.
DHW Burner Hours
Number of hours that the appliance has burned for Domestic Hot Water.
Error logging.
Error logging is available. This functionality is linked to the Real-Time Clock functionality.
Errors will be logged for a stand-alone system or for a complete cascade system (based on the cascade settings).
The PB display will monitor the error codes it receives from the water heater(s) and if an error code is a new error
code the error will be stored in the error log. An error will be logged with a (real-time clock) time stamp (date and
time) when the error was detected and a water heater ID of the water heater on which the error was detected.
The error log can be viewed from the error log menu, which is located in the information menu.
Menu
Domestic Hot Water (DHW)
Information
Settings
System test
i
Information
Water heater Status
Water heater History
Error Log
Service
!
Error Log
Error Log
Filter Error Type
Clear Error Log
Disabled
(Sub) Menu item
Description
Error Log
Show the error log (based on the selected filter options)
Filter Error Type
Filter errors based on the Error Type (Lockout/Blocking)
Filter Water heater ID (Cascade System
Filter errors based on Water heater ID (Managing, Dep 1, Dep 2,
Clear Error Log
Clear the error log (protected by password)
When no filtering option is selected (Disabled) the error log will show all errors for that category. So, if both filters
are disabled, the error log will show all the errors in the log.
Error Log
A014 (14) Lockout
Air Switch Not Closed
Wed 04-11-2018 14:50 1/32
▼
The error log screen will show on the first line: Water heater ID for which water heater the error was detected
(cascade system only), Error Code, (internal) Error Number, Error Type (Lockout/Blocking).
The second line will show the Error Description.
The bottom line will show the Time Stamp (date and time) when the error was detected (in the format as configured
in the Date Time Settings menu), and also the selected error index from the total number of errors in the (filtered)
error log. Only Time Stamp, Code and Description is displayed.
Содержание HWB-299
Страница 2: ......
Страница 7: ...E93 1801EN171 HWB installation manual 7 1 SAFETY GUIDELINES...
Страница 8: ...E93 1801EN171 HWB installation manual 8 CONSIGNES DE S CURIT...
Страница 65: ...E93 1801EN171 HWB installation manual 65 Ladder Logic Diagram...
Страница 66: ...E93 1801EN171 HWB installation manual 66 Electrical schematics...
Страница 67: ...E93 1801EN171 HWB installation manual 67...
Страница 119: ...E93 1801EN171 HWB installation manual 119 22 SPARE PARTS...
Страница 120: ...E93 1801EN171 HWB installation manual 120 68 68 73...
Страница 123: ......