Eco Air EPA-09CRN8 Скачать руководство пользователя страница 1

 MOBILE TYPE AIR CONDITIONER

 (Local Air Conditioner)

Owner’s Manual & 
Installation Manual

IMPORTANT NOTE:

Read this manual carefully before installing 

or operating your new air conditioning 

unit. Make sure to save this manual for 

future reference.

55        54

EPA-09CRN8

R32

22,2 kg(48,9 lb)

10      108

9,000

51.5

Содержание EPA-09CRN8

Страница 1: ...ner Owner s Manual Installation Manual IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference 55 54 EPA 09CRN8 R32 22 2 kg 48 9 lb 10 108 9 000 51 5 ...

Страница 2: ...recautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation Kit Installation Troubleshooting Tips 03 11 11 12 12 12 12 13 13 14 16 18 18 19 21 21 21 21 22 ...

Страница 3: ...g is grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shock Voltage information can be found on the nameplate of the unit Your unit must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker the fuse or circuit bre...

Страница 4: ...hould be supervised to ensure that they do not play with the appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard CAUTION Disconnect the power if strange sounds smell or smoke ...

Страница 5: ...scapes endangers your health when hazar do us substances leak into the ground water and find their way into the food chain Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the presence of inflammable substances or vapour such as alcohol insecticides petrol etc Always transport your air conditioner in a vertical position and stand on a stable level s...

Страница 6: ...Ne pas percer ni bruler Attention les frigorigènes peuvent être inodores Please follow the instruction carefully to handle install clear service the air conditioner to avoid any damage or hazard Flammable Refrigerant R32 is used within air conditioner When maintaining or disposing the air conditioner the refrigerant R32 or R290 shall be recovered properly shall not discharge to air directly No any...

Страница 7: ...nside the package will not cause a leak of the refrigerant charge The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be s...

Страница 8: ...cuit is being used the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed 1 During repairs to sealed components all electrical supplies shall be disconnected from the ...

Страница 9: ...he following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the re...

Страница 10: ...b Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available and being used correctly The recovery process is supervised at all times by a competent person Recovery equipment and cylinders conform to the appropriate standards d Pump down refrigeran...

Страница 11: ...s In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant releas...

Страница 12: ...o the portable air conditioners themselves The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diameter 150mm Length 1 5m Diameter 130mm Length 1 5m The Energy rating and noise information for unit with 3 meters extended exhaust duct is not assessed For some models NOTE We recommend that operating the unit at room temperature below 35 C Since there is a risk that the u...

Страница 13: ...determine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amount of heat it can remove from a room A higher Why is the cooling capacity lower on newer models than on older units number means more cooling power for a larger room Be sure you are comparing only n...

Страница 14: ...Hose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE D 1 set 1 pc Window Slider B Remote Controller and Battery only for remote control models 1 pc Wall Exhaust Adaptor A only for wall installation models 2 pc Foam Seal A Adhesive 1 pc Wall Exhaust Adaptor B with cap only for wall installation models ...

Страница 15: ...liders once they are adjusted to the Proper length Window slider A Window slider B Bolt Window slider A Window slider B Window slider C Bolts Step Two Install the Exhaust hose assembly to the unit Push the Exhaust hose into the airoutlet opening of the unit along the arrow direction MODEL B MODEL A MODEL C 1 2 Bolt Bolt Bolt 1 2 3 1 2 1 2 3 Bolt Bolt Bolt 1 2 3 4 Bolt Bolt Bolt 1 4 Bolt Window Sli...

Страница 16: ...sash and frame as shown Foam seal B Adhesive type shorter Foam seal A Adhesive type Or Or Window slider A Window slider B if required Foam seal C Non adhesive type 3 Cut the non adhesive foam seal C strip to match the width or height of the window Insert the seal between the glass and the window frame to prevent air and insects from getting into the room 2 Insert the window slider assembly into th...

Страница 17: ... actual shape shall prevail NOTE Cover the hole using the adaptor cap when not in use max 120cm or 47 inch min 30cm or 12 inch Expansion anchor position Adaptor cap Wall Exhaust Adaptor B Or 5 Insert the window slider adaptor into the hole of the window slider Type 2 Wall Installation For some models 1 Cut a 125mm 4 9inch hole into the wall for the Wall Exhaust Adaptor B 2 Secure the Wall Exhaust ...

Страница 18: ...r error on some models E4 Display panel communication error EC Refrigerant leakage detection malfunction on some models Shows protection code P1 Bottom tray is full Connect the drain hose and drain the collected water away If protection repeats call for service NOTE When one of the above malfunctions occurs turn off the unit and check for any obstructions Restart the unit if the malfunction is sti...

Страница 19: ...ss MODE and UP buttons at the same time for 3 seconds to turn off Wireless function and the LED DISPLAY shows OF for 3 seconds press MODE button and UP to turn on Wireless function and the LED DISPLAY shows On for 3 seconds NOTE When you restart the wireless function it may take a period of time to connect to the network automatically NOTE Under AUTO mode both the AUTO mode and the actual operatio...

Страница 20: ...e sure the hose is secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent leakage Continuous drain...

Страница 21: ...he unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold Turn off the appliance and unplug it Clean the air filter according to the instructions in the previous section Reinstall the...

Страница 22: ...an to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double check the cooling area Turn off the unit disconnect the hose check for blockage and reconnect the hose Remove the heat sources if possible The unit is noisy and vibrates too much The unit makes a gurgling sound The ground is not level Place the unit on a flat level surface ...

Страница 23: ......

Страница 24: ...ns are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version ...