background image

 

USER MANUAL

 

STROBOLED

 

LARYNGOSTROBOSCOPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABOUT THIS MANUAL 

Version: 2019.04.01 

Year: 2019 

Language: English 

All the rights to this manual are reserved, especially reproduction, publication and translation rights. No portion of this manual may be 
reproduced by no means (photocopy, microfilm or other methods) without previous written authorization from ECLERIS. Neither can it 
be reproduced, multiplied or published through any electronic data processing form. 

The  information  contained  in  this  manual  may  be  modified  or  broaden  without  previous  notification,  without  it  representing  an y 
responsibility to ECLERIS. 

 

 
ECLERIS USA. 

11801 NW 100th Rd 
Suite 17 
Medley, FL 33178 
Phone: +1 786 483 7490

 

 

 
 
 

 

 

CMC Medical Devices & Drugs S.L. 

C/  Horacio  Lengo  Nº18,  CP29006, 
Málaga, Spain 
Ph. +34951214054 
Email: [email protected]

 

 

Содержание STROBOLED

Страница 1: ...s without previous written authorization from ECLERIS Neither can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be m...

Страница 2: ...AND SET UP 7 4 1 PREPARATION FOR USE 7 5 EXAMINATION AND OPERATION 8 5 1 REVISION 8 5 2 OPERATION 9 5 2 1 DEVICE SETTINGS 9 5 2 2 OPERATION MODES AND FEATURES 11 6 PERFORMING AN EXAMINATION 12 6 1 GE...

Страница 3: ...pment If you have any doubt regarding the contents of this guide the use or safety of the equipment please contact your local provider or the nearest Ecleris office 2 1 WARNINGS It is important to rea...

Страница 4: ...authorized by ECLERIS ECLERIS will not be liable for the damage caused by repairs or service performed by not authorized personnel In case of any problem the system must be laid a plane surface and po...

Страница 5: ...ubglottal pressure exceeds by volitive effect the resistance created by the closure of the vocal folds the inferior border begins to open and this aperture generates an undulating movement of the fold...

Страница 6: ...ressure and lower the fundamental frequency the larger the amplitude It can be impaired under conditions such as vocal fold stiffness a reduction in the lateral movement is observed or increased by pr...

Страница 7: ...ith fuse holder 4 INSTALLATION AND SET UP 4 1 PREPARATION FOR USE Before installing the device you should carefully read the whole manual Should you have any questions or doubts concerning the operati...

Страница 8: ...eck if the fans work If they damaged and don t work turn the equipment off immediately to avoid any high temperature failure in the LEDS system It should always be connected to ground of the operation...

Страница 9: ...ts use 5 2 OPERATION This section details the procedure for setting up the device and checking its operation It should be conducted once the device is installed and during the course of maintenance ch...

Страница 10: ...ight settings Press the Light settings button to access the light settings screen In this screen you will be able to adjust the light settings both in Stroboscopic Mode Stroboscopic light and in Conti...

Страница 11: ...80 Hz to 1500 Hz The frequency is fine tuned pressing the control to the right to increase it and to the left to reduce more accurately the frequency value This mode is used in case the patient s voic...

Страница 12: ...opy Once the patient is willing to begin the examination he or she must sit leaning forward The neck of the patient must be undressed so that the contact microphone can be placed The microphone must b...

Страница 13: ...nd such as i as in the word it a as in the word car u as in the word blue etc This is due to the fact that correct automatic voice recognition is not achieved which may occur because of low intensity...

Страница 14: ...sterilize or immerse the device or its accessories The cleaning disinfection and sterilization of accessories not provided by ECLERIS must be performed following the instruction provided by their manu...

Страница 15: ...shock Class I Applicable part type BF Grade of water protection IPX0 Function Mode Continuous Power supply 100 240VAC N of phases 1 single phased Current type Frequencies 50 60 Hz Max Power Consumptio...

Страница 16: ...the on off switch turns on but the LED system does not LED system exhausted Contact the nearest Technical Service Burnt internal fuse or defective board Contact the nearest Technical Service Incorrect...

Страница 17: ...lance and adjust the image controls till you find a better image Poorly connected or damaged fiber optic cable Verify that the fiber optic cable is correctly placed and it is in good condition If the...

Страница 18: ...WARRANTY ECLERIS states that the StroboLED has complied with the required Quality Control verification and has no manufacturing defects This guarantees the appropriate functioning under adequate use i...