ABOUT THIS MANUAL 

Version: 2019.04.01 

Year: 2019 

Language: English 

All the rights to this manual are reserved, especially reproduction, publication and translation rights. No portion of this manual may be 
reproduced by no means (photocopy, microfilm or other methods) without previous written authorization from ECLERIS. Neither can it 
be reproduced, multiplied or published through any electronic data processing form. 

The  information  contained  in  this  manual  may  be  modified  or  broaden  without  previous  notification,  without  it  representing  an y 
responsibility to ECLERIS. 

 

 

EUSA GLOBAL Llc. 

11801 NW 100th Rd 
Suite 17 
Medley, FL 33178, U.S.A. 
Phone: +1 786 483 7490

 

 

CMC Medical Devices & Drugs S.L. 

C/  Horacio  Lengo  Nº18,  CP29006, 
Málaga, Spain 
Ph. +34951214054 
Email: [email protected]

 

 

 

 

 

 

Содержание MICROSTAR C-100A5E

Страница 1: ...m or other methods without previous written authorization from ECLERIS Neither can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modified or broaden without previous notification without it representing any responsibility to ECLERIS EUSA GLOBAL Llc 11801 NW 100th Rd Suite 17 Medley FL 33178 U S A Phone 1 786 483...

Страница 2: ...TELESCOPIC COLUMN MODEL C 100A5E 9 4 2 FOCAL LENS MOUNTING 11 4 3 BEAM SPLITTER AND CAMERA INSTALLATION 11 4 3 1 IMAGE ORIENTATION 13 4 4 REVISION 13 5 OPERATION FUNCTIONS 13 5 1 INTERPUPILLARY DISTANCE ADJUSTMENT 14 5 2 DIOPTRIC CORRECTION ADJUSTMENT 14 5 3 MAGNIFICATION VARIATION 14 5 4 COLOR FILTER 14 6 MANIPULATION MOVEMENTS 15 6 1 HEAD ROTATION AXIS 15 6 2 HEAD TILT 15 6 3 SHIPMENT 15 7 MAINT...

Страница 3: ...USER MANUAL COLPOSCOPE C100A5E Page 3 of 20 INMANUUIN163 Rev 2019 04 01 ENG 11 WARRANTY 20 ...

Страница 4: ...ctions and or ignoring the following advice Keep the device out of children reach Do not install the device close to heat sources like stoves Do not use the colposcope in places where there is explosion danger Always install the device on top of firm and horizontal surfaces on a perfect ventilated area Do not block the ventilation screens This ventilation must assure good air flow Avoid device exp...

Страница 5: ... colposcope and handling it according to instructions If as a consequence of Inadequate use of the equipment No use of this manual Poor care and maintenance of the equipment Repair and manipulation by unauthorized personnel any material or personal damage were caused to third parties ECLERIS the manufacturer and the supplier of the equipment shall not assume any responsibility for such damages Do ...

Страница 6: ...OR STAND TELESCOPIC COLUMN MODEL C 100A5E Components 1 Base with wheels 1 Telescopic Column 1 90 Arm 1 Everlux Mini Light Source 1 Head with 1 objective lens 1 Binocular 2 Eyepieces 1 Fiber optic cable 1 3 mts Power cable 1 Cover 1 User s manual 1 10 mm Allen key 1 4 mm Allen key 1 Head 2 Head handle 3 Fiber optic cable 4 Regulation of head rotation command 5 Regulation of elbow rotation command 6...

Страница 7: ...ication selector 2 Micro focus adjustment 3 Objective lens 4 Green filter 5 Head handle 6 Fiber optic cable 7 Eyepiece rubber 8 Eyepiece 9 Binocular body 10 Head body 11 Balance movement control 12 Head fork pole 3 3 3 LIGHT SOURCE 3 3 3 1 FRONT PANEL 1 On Off switch 2 Light Intensity Control Dimmer 3 Fiber optic cable connector 4 Camera connector video input ...

Страница 8: ...phic camera adapter Converter of beam splitter to endocoupler C Mount 45º inclined binocular Straight binocular CCD Video Camera NTSC PAL Eyepieces 10X 200 mm Objective lens 250 mm Objective lens 300 mm Objective lens 400 mm Objective lens Digital capturing and documentation system Ecleris ENDODIGI 4 INSTALLATION AND SET UP Experienced personnel are not required for the installation of the Ecleris...

Страница 9: ...ODEL C 100A5E 1 Place the colposcope s base in a vertical position 2 Insert the column into the base and hold it by mean of the provided 10mm Allen screw Place the washer between the screw and the base as shown in the picture below 3 Stand the base on the floor and insert the 90 arm into the column 4 Attach the light source to the column using the 4 Phillips screws provided 5 Insert the head fork ...

Страница 10: ... that the marks are aligned Adjust the binocular screw to achieve the best possible seat 7 Attach the eyepieces to the binocular Unfold the rubber protectors surrounding the eyepieces Note If the user wears eyeglasses leave the rubber protectors folded 8 Attach one end of the fiber optic cable to the light source and the other end to the head ...

Страница 11: ...crew the lens to the head tightening until the micro focus adjustment reaches the desired position Counterscrew the nut for proper fixation of the lens 4 3 BEAM SPLITTER AND CAMERA INSTALLATION 1 Remove the binocular if it is already placed 2 Tightly screw the camera to the beam splitter until its end Do not over tight the video camera to the beam splitter in order to avoid mechanism damage 3 Plac...

Страница 12: ...t or image during this procedure 9 Set the oculars to its middle position no dioptric correction 10 Rotate the magnification selector up to the maximum factor 2 5X 11 Looking through binoculars focus the image using the micro focus knob until all magnifications are in focus parafocusing 12 Adjust the oculars dioptrics to correct eyesight deviations until the visualized image gets comfortable and s...

Страница 13: ...arting up the Ecleris Microstar C 100A5E Colposcope please go through the following check list Check that the voltage to be used is within the specified power voltage range Verify that the electrical network used has its grounding connection in perfect conditions and that it makes perfect contact with the equipment Check that the fuse holder has fuses installed and that are the correct ones 2 x T3...

Страница 14: ...urce should be turned off Never touch the fiber optic end Do not look directly into the end of the light guide cable or the end of the objective lens of the colposcope It is recommended to connect the fiber optic cable before you turn on the light source 5 1 INTERPUPILLARY DISTANCE ADJUSTMENT To perform this adjustment you must hold the body of the binocular with both hands and turn them simultane...

Страница 15: ...oscope has been designed to be moved over short distances within a doctor s office or room If it is necessary to move the colposcope over larger distances special attention should be paid to the following recommendations Set the brakes to avoid movements Place the cover on the colposcope Disconnect the power cable from the electrical network and tie it firmly to the colposcope s column Do not circ...

Страница 16: ... flammable products were used do not turn the light source on until one 1 hour after the cleaning since an explosive mixture may be produced Do not use detergents solvents or any other abrasive agents Do not send to the autoclave any part or component of this device that is not specifically marked as autoclavable Do no sterilize or immerse the device or its accessories The cleaning disinfection an...

Страница 17: ...ork 8 TECHNICAL SPECIFICATIONS MICROSTAR C 100A5E COLPOSCOPE OPTICAL SYSTEM Composed of apochromatic lenses with a fungus resistant coating BINOCULAR TUBES 45 Inclined 55 80 mm Straight 45 to 80mm Inclinable 50 to 85mm OBJECTIVE LENS F 200 250 300 400 mm one included MAGNIFICATIONS Apochromatic five steps magnification changer through a click stop revolving mechanisms FINE FOCUS Manual EYEPIECES 1...

Страница 18: ...mmer FLOOR STAND TELESCOPIC COLUMN BASE 640 x 640 mm HEIGHT REGULATION 97 5 a 120 mm WEIGHT 29 7 pounds 13 5Kg SERVICE CONDITIONS TEMPERATURE 50 104 ºF HUMIDITY 35 75 relative humidity PRESSURE 700 1060 hPa STORAGE AND TRANSPORTATION CONDITIONS TEMPERATURE 22 122 ºF HUMIDITY 10 95 relative humidity PRESSURE 500 1060 hPa 9 TROUBLESHOOTING The following table indicates the most common problems and t...

Страница 19: ... working Turn the equipment off immediately and contact the closest Technical Service If the problem cannot be solved please contact your local distributor or the closest ECLERIS office and request technical service 10 TECHNICAL SERVICE The Ecleris Microstar C 100A5E Colposcope should be repaired and or maintained exclusively by ECLERIS trained and qualified personnel in authorized installations a...

Страница 20: ...d Quality Control verification and has no manufacturing defects This guarantees the appropriate functioning under adequate use in agreement with the indications of this manual The warranty period is for one 1 year as from the date of purchase invoice ECLERIS shall not be liable for any damage caused to by the Colposcope due to incorrect use negligence incorrect cleaning or storage Any repairs made...