27
6.2
Login by Browser
To access VEO-MXH88D WEB settings,
it is necessary to enter the base unit IP address in
an internet browser.
•
Default IP address:
192.168.1.168
•
Default username:
admin
•
Default password
:
123456
6.3
EDID Management
The device includes
4 EDID modes
: Default EDID, User EDID, Output EDID, Temp1, control
EDID by WEB and RS-232. Factory Default: Default1 4K60 444 2CH.
Instructions are as follows:
Send instruction:
#edid_d in%8,d source=%d switch EDID, “in%8,d” parameter need to
input 255 or 0~7 (255 means all input), source=%d=0~24(Correspond the table below)
EDID MODE
EDID
Index
EDID
Default EDID
0
4096x2160@60-444 HLG 2CH (default)
1
4096x2160@60-420 HLG 2CH
2
4096x2160@30-444 HLG 2CH
3
1920x1080P@120-444 HLG 2CH
User EDID
4-7
User EDID is set by user, with power-off memory function,
new EDID will auto-cover old EDID.
Output EDID
8-15
Copy output 1-8 ports' EDID with storage function.
without power-off memory
Temp1
24
Temporary EDID
The above EDID
supports 4K Downscaler 1080P.