17
5.9
Remote Controlling
VEO-MXH44D
can be remotely controlled over RS-232 or TCP/UDP communications
protocol.
•
For RS-232
serial communication: enter the selected parameters on
•
For TCP/UDP
communication: enter the current VEO-MXH44D IP address and Port:
5000 for TCP or 5001 for UDP commands.
5.9.1
Series Port Setting
The
serial parameters for a correct transmission
are:
Baud rate 115200 (by Default)
|
Data bits 8
|
Stop bits 1
|
Parity None
|
Flow
control None
For a correct communication, both the host PC and VEO-MXH44D need to have the
same baud rate amongst the available options.
5.9.2
Command List
•
All commands start with “#”
•
“_” the underline cannot
be omitted.
•
Command head, Parameter and target need to add one “SPACE”.
Command Code
Description
Command Return
#video_d out[x] matrix=[y]
Switches Video Output channel [x] to Input
channel [y]
PARAMETERS DESCRIPTION
•
[x]: Output channel number, ranging from 1 to 4. If
[x]=0, all output
•
[y]: Input channel number, ranging from 1 to 4
<Ouput[x] : Video Matrix> [Data=[y-1] : Input [y]]
#video_d out[x] onoff=[y]
Turns on and off Output channel [x]
PARAMETERS DESCRIPTION
•
[x]: Output channel number, ranging from 1 to 4. If
[x]=0, all output
•
[y]:
ON = 1
OFF = 0
<Ouput[x] : Video OnOff> [Data=[y-1] : Input [y]]