11
5.6. Programming and control Ethernet port
The RJ45 connector labeled ETHERNET allows the connection of the equipment to an
Ethernet local network (LAN), being compatible with the following purposes:
•
Management from the EclerNet Manager application, by direct connection (CAT5
cable or higher) of a computer with a MIMO4040CDN unit or using an Ethernet
network as a link between both. Refer to the EclerNet Manager Application manual
for more information.
•
Connection to third party control equipment. (Crestron, AMX, Extron, Medialon, etc.
are registered brands from their respective owners). Protocol used: Ecler TP-NET.
Refer to the TP-NET protocol manual for more information.
•
UCP: EclerNet project remote control service using customisable graphical control
panels. MIMO4040CDN can act as a server for these panels, included in an EclerNet
project, and also be remotely controlled by UCP panel client devices
(WPNETTOUCH, Android® or iOS® mobile devices, Windows® devices, etc.).
5.7. Control remote RS-232 port
The RS-232 port with DB9 connector built into the rear panel allows an external device
to communicate with a MIMO4040CDN unit via serial connection. This connection will
use the syntax of the TP-NET protocol so that the external device can obtain the value of
some of the parameters of the MIMO4040CDN unit (by means of "GET" commands)
and/or modify these values ("SET" commands). Refer to the TP-NET protocol manual for
more information.
The serial connection must comply with the following characteristics:
•
Baud rate: 115200 (fixed, no auto negotiation)
•
Data bits: 8
•
Parity: None
•
Stop bits: 1
•
Flow control: None