13
9.2. Switch configuration
The default settings for the equipment switches are as follows:
SENS:
switches at 0dB
MODE
: ST
SRC:
IN 1 – 2
PHANTOM INPUT 1&2
: OFF
REMOTE POWER
: OFF
To change the input sensitivity (SENS), move the corresponding input switch to set it to
0, -20 or -40dB.
To change the configuration of the OUT A/B outputs, the input selection switches (SRC)
and mono/stereo output switches (MODE) can have the following positions with their
corresponding output configuration:
POSITION
SWITCHERS
OUTPUT CONFIGURATION
(OUT A/B = TX A/B)
SRC = IN 1 – IN 2
MODE = ST
OUT A = IN 1
OUT B = IN 2
SRC = IN 1 – IN 2
MODE = MONO
OUT A = IN 1 + IN 2
OUT B = IN 1 + IN 2
SRC = IN 3 – IN 4
MODE = ST
OUT A = IN 3
OUT B = IN 4
SRC = IN 3 – IN 4
MODE = MONO
OUT A = IN 3 + 4
OUT B = IN 3 + 4
SRC = ALL
MODE = ST / MONO
OUT A = IN 1 + IN 2
OUT B = IN 3 + IN 4
To activate the phantom power to the microphones as needed, the PHANTOM IN 1&2
switch must be turned ON. In the same way, to activate the remote power supply to
another GENIO unit, the REMOTE POWER switch must be turned ON.
Содержание GENIO
Страница 16: ...16 14 BLOCKS DIAGRAM ...