Graphic Symbol Explanation 

 

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to 
alert the user to the presence of uninsulated “dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to 
persons. 

 

The exclamation point within an equilateral triangle is intended to alert the user to the 
presence of important operating and maintenance (servicing) instructions in the literature 
accompanying the appliance. 

 

The lightning flashes printed next to the OUTPUT terminals of the amplifier are intended 
to alert the user to the risk of hazardous energy. Output connectors that could pose a risk 
are marked with the lightning flash. Do not touch output terminals while amplifier power is 
on. Make all connections with amplifier turned off.

 

 
WARNING: To prevent fire or shock hazard, do not expose this equipment to rain or moisture. 

 
IMPORTANT SAFETY INSTRUCTIONS 

 

1. 

Read these instructions.

 

2.  Keep these instructions. 
3.  Heed all warnings. 
4.  Follow all instructions. 
5.  Do not use this apparatus near water. 
6.  Clean only with dry cloth. 
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 

(including amplifiers) that produce heat. 

9.  Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has 

two blades with one wider than the other. A grounding type plug has two blades and a third 
grounding prong. The wide blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience 

receptacles, and at the point where they exit from the apparatus. 

11. Only use attachments/accessories specified by the manufacturer. 
12. Unplug the apparatus during lightening sorts or when unused for long periods of time. 

13. 

Refer all servicing to qualified personnel. Servicing is required when the apparatus has been 
damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped.

 

14. Disconnecting from mains: Switching off the POWER switch all the functions and light indicators 

of the amplifier will be stopped, but fully disconnecting the device from mains is done unplugging 
the power cord from the mains input socket. For this reason, it always shall remain readily 
operable. 

 

Содержание eGPA SERIES

Страница 1: ...USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D UTILISATION BEDIENUNGSANLEITUNG eGPA SERIES ...

Страница 2: ...ear any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided ...

Страница 3: ...Limiter circuit 06 3 6 Output connections 06 4 OPERATION AND USAGE 06 4 1 Start up 06 4 2 Input attenuators 06 4 3 Indicators 07 5 CLEANING 07 6 FUNCTION DIAGRAM 08 7 FUNCTION LIST 09 8 TECHNICAL CHARACTERISTICS 34 9 BLOCK DIAGRAM 35 All numbers subject to variation due to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in manufacturing or design w...

Страница 4: ...erviceable parts inside the amplifier Failure to do so may result in malfunction of the device and may even damage the device 1 Avoid turning on the device without speakers connected to its outputs and without setting the volume gain controls to the minimum 2 Always use shielded cables to make the connections between devices 2 INTRODUCTION The Ecler Essentials eGPA amplifier series offers the reno...

Страница 5: ... by a set of fuses Should a fuse blow it must be replaced immediately by one with identical rating Should it blow again please contact our Technical Service Department NEVER REPLACE THE FUSE WITH ANOTHER ONE WITH A HIGHER VALUE CAUTION Fuse substitutions have to be performed by a qualified technician 3 3 Input signal connections The signal input connectors are of EUROBLOCK 12 13 and electronically...

Страница 6: ...ut connector Optionally you can connect the other two output terminals to each other in order to improve the distortion value They have to be connected with a short cable The connection cable that joins the amplifiers outputs and the loudspeakers must be of good quality sufficient section and as short as possible This is most important when the distances to cover are long ones 4 OPERATION AND USAG...

Страница 7: ...m takes into account possible variations in the supply voltage always giving a real indication CLIP indicators light up to the beat of low frequencies when working at high power levels it s normal as low frequencies are those with higher energy content You must take care that these indicators do not remain continuously lit SP Signal Presence indicators 1 3 indicate the presence of a valid signal a...

Страница 8: ...8 6 FUNCTION DIAGRAM ...

Страница 9: ...ndby status indicator 8 TH thermal protection indicator 9 ON power indicator 10 AUTO STANDBY switch 11 Power switch 12 CH 1 input 1 Euroblock connector 13 CH 2 input 2 Euroblock connector 14 STEREO MONO BRIDGE selector 15 CH 1 output 1 Euroblock connector 16 CH 2 output 2 Euroblock connector 17 AC socket connector NOTE Listed functions are for two channel models for models with more than two chann...

Страница 10: ...D Noise 1kHz Full Pwr 0 05 0 05 0 05 S N N 20Hz 20kHz 1W 4Ω 85dB 85dB 85dB CMRR 55dB 55dB 55dB Damping factor 1kHz 8Ω 150 150 150 Channel crosstalk 1kHz 55dB 55dB 55dB Input Sensitivity Impedance 0dBV 20kΩ 0dBV 20kΩ 0dBV 20kΩ Anticlip 2dBV input 1 THD 1 THD 1 THD Mains Voltage See characteristics in the back of the unit Power consumption pink noise 1 8 power 4Ω 63W 74VA 113W 130VA 226W 260VA Power...

Страница 11: ...35 9 BLOCK DIAGRAM 9 DIAGRAMA DE BLOQUES 9 SCHEMA DE BLOCS 9 BLOCKSCHALTBILD eGPA2 150 eGPA4 150 ...

Страница 12: ...36 eGPA8 150 ...

Страница 13: ...37 eGPA8 150 NEEC AUDIO BARCELONA S L Motors 166 168 08038 Barcelona Spain INTERNET http www ecler com 50 0300 01 00 ...