5.2. Connections 

WPNETTOUCH has 2 connectors available for the EclerNet operation. Both are located 
behind  the  rear  panel  connections  plastic  cover,  fixed  to  the  WPNETTOUCH  unit  back 
panel with 2 screws: 

 

DC  Power:  round  jack  for  connection  to  the  universal  power  supply  provided 
with the product, 12 VDC, 2A 

 

Ethernet Port: RJ45 connector of the unit's network communication interface, as 
well as PoE DC supply compatible, in case the network switch is able to provide 
PoE (Power over Ethernet) to it. It can be directly connected (point to point) to a 
single  EclerNet  device,  for  its  direct  and  exclusive  control,  or  to  an  Ethernet 
switch  port  belonging  to  the  network  the  rest  of  the  EclerNet  devices  of  the 
installation  are  connected  to.  The  connecting  cable  can  be  a  standard  or 
crossover CAT5 or higher cable. 

6.

 

OPERATION 

From EclerNet Manager application, it’s possible to create remote control panels for the 
system  (UCPs)  to  manage  one  or  more  MIMO4040DN,  MIMO88,  MIMO88SG, 
MIMO1212SG, NXA, DUO-NET PLAYER, etc. units in a networked installation. Each panel 
can consist of one or more pages that include graphics, text, volume controls, buttons, VU 
meters, LED indicators, and so on. In this way each remote user may have his own control 
panel(s)  custom  tailored  to  his  needs  and  privileges,  and  in  one  system,  very  simple 
control panels for some users can coexist with others, more complex and having higher 
levels of authorization. 

Once  the  UCPs  are  created,  included  in  an  EclerNet  project,  the  network  needs  a  web 
server for the potential web clients that will control the installation thanks to the UCPs 
they can recall from the web server, locally visualized and managed. The web server can 
be one of these types of devices: 

 

A WPNETTOUCH unit running the EclerNet project previously created with the 
EclerNet Manager application 

 

A  WPmSCREEN  unit  running  the  EclerNet  project  previously  created  with  the 
EclerNet Manager application 

 

A MIMO4040DN matrix running the EclerNet project previously created with the 
EclerNet  Manager  application  (yes,  the  MIMO4040DN  does  include  project  & 
UCP webserver features in its engine!) 

 

A  Windows®  PC  running  the  created  EclerNet  Manager  project  in  "Deploy" 
mode 

Содержание EclerNet WPNETTOUCH

Страница 1: ...WPNETTOUCH DIGITAL CONTROL EclerNet Control Touch Screen USER MANUAL ...

Страница 2: ...TIONS 6 5 1 Installation 6 5 2 Connections 7 6 OPERATION 7 7 LOCAL CONFIGURATION OF THE UNIT 9 7 1 Screen Configuration menu 10 7 2 Device Configuration menu 12 7 3 Network Configuration menu 13 7 4 Information Tools menu 14 8 CONNECTION TO A UCP SERVER 16 9 PACKAGE CONTENTS 18 10 FUNCTION LIST 18 11 FUNCTION DIAGRAM 19 12 TECHNICAL FEATURES 20 ...

Страница 3: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Страница 4: ... any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Disconnecting from mains switching off the POWER switch all the functions and light indicators of the amplifier will be stopped but fully disconnecting the device from mains is don...

Страница 5: ...IMO88SG MIMO1212SG digital matrices NXA series digital audio managers DUO NET PLAYER units etc It is fully programmable through the EclerNet Manager application Refer to the EclerNet Manager Application manual for more information The EclerNet Manager application is available for download at www ecler com The WPNETTOUCH is suitable for wall mount installation using the included VESA 75 bracket or ...

Страница 6: ... both plates have been assembled and secured the unit can be fixed fitting them together and screwing the included security screw with the included tool for it Note the VESA75 standard allows mounting the WPNETTOUCH unit using other third party VESA75 brackets or stands Desktop mount the unit includes a stick shaped support that can be screwed to a thread at the back panel of the WPNETTOUCH unit o...

Страница 7: ...NET PLAYER etc units in a networked installation Each panel can consist of one or more pages that include graphics text volume controls buttons VU meters LED indicators and so on In this way each remote user may have his own control panel s custom tailored to his needs and privileges and in one system very simple control panels for some users can coexist with others more complex and having higher ...

Страница 8: ... existing that acts as a web server can be its own web client Computers tablets and the like running an Internet browser Internet Explorer Google Chrome Mozilla Firefox etc Devices with Android operating system tablets smartphones running Ecler UCP v2 app Devices with Apple iOS iPad iPhone etc running Ecler UCP v2 app Any of them can recover and operate UCPs pointing to the web server s IP address...

Страница 9: ... of the device itself The same settings are remotely accessible when the screen is under the control of a remote computer running the EclerNet Manager application Local access to the configuration menus can be done by clicking on the SETUP icon from the home page of the unit The available configuration menus are the following ...

Страница 10: ...fter 10 seconds of user inactivity on the touch screen The available modes are ON always lit DIMMED and OFF unlit Backlight Intensity brightness intensity of the screen when it is not in sleep mode Auto Zoom Panels when activated the graphic control panels UCPs are automatically resized to match the maximum visible area no matter the original resolution they were created in the EclerNet Manager pr...

Страница 11: ...t for the layout of the controls buttons sliders knobs etc on each UCP page during its design the corners must be as free as possible if these OSD buttons will be used for scrolling between pages top ones and always free in the case of the bottom ones icon bar display Scroll by OSD Buttons enables disables the scroll action between pages pressing the top corners even the OSD buttons are hidden Scr...

Страница 12: ...lly functional taking control of the hardware devices that are included in it MIMO4040DN MIMO88 NXA units etc and serving the UCP panels it contains to potential UCP clients on the network o Disabled the EclerNet Local Project is deactivated releasing the control over all included hardware MIMO4040DN MIMO88 NXA units etc and consequently also ceasing to serve UCPs for clients Warning In the disabl...

Страница 13: ...e the devices controlled by the unit by setting the Enable UCP Server option on NO 7 3 Network Configuration menu This menu allows modifying the network connection parameters of the WPNETTOUCH unit IP address network mask and gateway Note neither the WPNETTOUCH nor any other EclerNet device supports the protocol of dynamic allocation of IP addresses Dynamic Host Configuration Protocol or DHCP so i...

Страница 14: ...ress IP Address configured for the WPNETTOUCH unit Local Project name of the project stored in the internal storage space of the WPNETTOUCH unit This project can be uploaded to the WPNETTOUCH unit using EclerNet Manager software app Available Storage internal storage space available to upload a project file which would include User Control Panels data and graphics Ethernet Address MAC address of t...

Страница 15: ...ect in memory replacing it with a blank project after warning that the process is irreversible Factory Defaults clears the entire configuration and all data in the unit restoring the factory default settings after warning that the process is irreversible Reboot reboots the unit ...

Страница 16: ...iding the UCP server the unit will connect to as a client The UCP server may be a computer a MIMO4040DN matrix yes it has an embedded UCP server in its engine another WPNETTOUCH WPmSCREEN unit or even the same WPNETTOUCH unit In any case the UCP server shall host and run an EclerNet Manager project that includes a series of UCPs which can be remotely managed by any UCP client ...

Страница 17: ...the Connect button Note in the list of detected server devices the name of the WPNETTOUCH unit under control will appear in green the one matching with the Local IP Address After selecting a server unit or an IP address using either of these two methods pressing the Connect button will confirm the selection and start the process of connecting to the server If this process is successful the UCPs th...

Страница 18: ...t screws set security screw tool Desktop mount stick shape support Quick User Guide and Warranty Card 10 FUNCTION LIST 1 Multitouch screen 2 VESA75 screw fixation holes 3 Desktop mount stick shape support fixation hole 4 Power supply connector 5 RJ45 Ethernet Port connector 6 Unused connections ...

Страница 19: ...19 11 FUNCTION DIAGRAM ...

Страница 20: ... Connectivity Ethernet Supports PoE Ethernet port Ethernet Base Tx 10 100Mb 1GB CAT5e or better up to 100m Power External power supply voltage 12VDC DC current max 350mA from 12V External Power Supply Voltage 125mA from PoE Mains power consumption 6W General Bracket mounting holes VESA 75mm Dimensions WxHxD 260x178x28 mm 10 2 x7 0 x1 1 Weight 700 gr 1 54 lb Accessories included AC power adapter 10...

Страница 21: ...e to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in design or manufacture that may affect these product specifications Motors 166 168 08038 Barcelona España 34 932238403 information ecler com www ecler com ...

Отзывы: