background image

 

 

 

6

 

PACK

AGE 

CO

N

TE

N

TS

 

FEATUR

ES

 

IN

ST

ALL
 

&

 

CO

N

N

EC

TE

CHN
IC

AL 

D

ATA

 

PANE

FUN

CT

IO

N

ST

ART

-UP
 

&

 

O

PE

RATI

O

N

 

PRE
CAUTI

O

N

T.O.C

3.1

 

MAIN FEATURES 

 

4 amplified outputs 
VersaPower 2400W. 

 

4 Dante

 outputs and 

4 Dante

 inputs. 

 

2 auxiliary outputs. 

 

4 analogue inputs. 

 

 MicroSD/SDHC card 
slot audio player. 

 

Internal  matrix  and 
signal processing. 

 

Web  application  for 
device configuration. 

 

Smart power 
management Smart 
VersaPower. 

 

Control  and  scheduled 
events for automation. 

 

Customize user panels. 

 

Remote control user 
application for 
iOS/Android/Web. 

 

Energy  saving  (Ultra-
low power consumption 
mode).

 

VersaPower 

is  the  amplification  technology,  developed  by  Ecler,  that  allows 

asymmetrical power distribution among amplified outputs, independent of load. 

Smart Versapower

 is the tool that allows automatic gain and sensitivity adjustment, 

to distribute in an easy and quick way, the total power among the amplified outputs. 

4.

 

INSTALL & CONNECT 

The equipment must be correctly grounded (ground resistance, Rg = 30 Ohm or less). The 
environment must be dry and dustless. Do not expose the unit to rain or water splashes, 
and do not place liquid containers or incandescent objects like candles on top of the unit.  

Do not obstruct the ventilation grilles

 with any kind of material. If the device requires any 

intervention and/or connection/disconnection, it must be first powered off. 

Do not handle the speaker output terminals

 with your device turned on, there are high 

voltages. The output cabling should be connected by a qualified technician. Otherwise only 
use pre-made flexible cables. There are no user serviceable parts inside the amplifier. 

Non-compliance  with  the  instructions  or  neglecting  warnings  may  cause 

malfunction or even damage the unit. 

 

Avoid turning on the device without the speakers connecte

d to its outputs and 

without having previously set the volume/gain controls to minimum level. 

 

Always use shielded cables

 to make connections between devices. 

 

In an amplifier, avoid placing the speaker output cables close to other signal 
cables

 

(micro,  line…).  This  may  cause  the  system  to  oscillate,  damaging  the 

amplifier and speakers. 

Содержание Dante VIDA-24Q

Страница 1: ...50 0429 0100 VIDA 24Q EN VIDA 24Q AMPLIFIERS Digital Amplifiers USER MANUAL PACKAGE CONTENTS FEATURES INSTALL CONNECT TECHNICAL DATA PANEL FUNCTIONS START UP OPERATION PRECAUTIONS...

Страница 2: ...logue Input Connections 8 4 4 Player and Micro SD Card 8 4 5 Digital Audio Inputs and Outputs 9 4 6 Amplified Output Connections 9 4 6 1 OUT MODE 9 4 6 2 Operation Example 10 4 7 Auxiliary Output Conn...

Страница 3: ...of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING A device with Class I construction shall be connected to a mains socket ou...

Страница 4: ...when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid...

Страница 5: ...s an asymmetrical power distribution and thanks to the Smart VersaPower tool it helps installers by facilitating a smart and fast configuration In addition the Class D amplification technology as well...

Страница 6: ...ground resistance Rg 30 Ohm or less The environment must be dry and dustless Do not expose the unit to rain or water splashes and do not place liquid containers or incandescent objects like candles o...

Страница 7: ...p This upward air flow will help to dissipate the heat generated inside It is advisable not to place power amplifiers under other appliances but upon these ones leaving at least one rack unit off betw...

Страница 8: ...onnection short circuit pin to pin 4 4 PLAYER AND MICRO SD CARD VIDA integrates a stereo audio player able to play audio files from local storage device microSD card for background music or voice mess...

Страница 9: ...oller For more information please refer to the developer s documentation www audinate com products software dante controller 4 6 AMPLIFIED OUTPUT CONNECTIONS The rear panel is fitted with two position...

Страница 10: ...inferior to 2 5mm2 and for superior distances 4mm2 4 7 AUXILIARY OUTPUT CONNECTIONS VIDA rear panel provides two analogues balanced line level auxiliary outputs Their independent routing mixing and p...

Страница 11: ...ork groups including general volume Also loading presets or playlists Please refer to the web application manual for more information on www ecler com 4 8 1 CONNECTING THE GPI REMOTE CONTROL PORTS The...

Страница 12: ...panel In this way it is possible to interact with external equipment such as motors for projection screens or movable partition walls lights sirens GPI inputs from other equipment etc 4 10 EXTERNAL MU...

Страница 13: ...lock synchronization calendar events automatic firmware updates and other tools Reception of 4 channels of digital audio Dante and sending of 4 channels of digital audio Dante Connection of third part...

Страница 14: ...mary Net1 incorporates Dante redundancy Recommended when using Dante with redundancy in two isolated LANs 4 Switch Mode ethernet ports perform as a 2 port switch and support control Dante Primary traf...

Страница 15: ...of them fails VIDA will automatically switch to the other recovering the audio transmission almost instantaneously Obviously to achieve total redundancy all Dante devices that are part of a system of...

Страница 16: ...ode both ports primary and secondary should never be connected simultaneously to network switches as this would create a loop that would cause network conflicts and disruption of the digital audio Dan...

Страница 17: ...dicator LED 8 Thermal indicator LED 9 Dante indicator LED 10 Data indicator LED 11 On Sleep indicator LED 6 2 REAR PANEL 1 Power switch 2 Mains socket base 3 Amplified outputs OUT1 4 2 pin Euroblock P...

Страница 18: ...type 2 pin Euroblock Pitch 7 62 mm Ref DEGSON 5EDGRC 7 62 Output configuration Lo Z Hi Z 70V 100V 4 8 2 Output mode selection per channel Rear panel DIP SWITCH selectors VERSAPOWER SYMMETRICAL All cha...

Страница 19: ...Universal regulated SMPS with PFC AC mains requirement 100 240 V 50 60Hz 10 Power factor correction 0 96 AC mains connector IEC C14 inlet POWER HEAT 230VAC 1 4 POWER 4 Power 848 W 888 VA Current Draw...

Страница 20: ...Efficiency 72 Cooling Fan Maximum fan noise 45dB PROTECTIONS DC protection Yes HF protection Yes Short circuit protection Yes Clip limiter Yes Long term limiter Yes Thermal protection Yes REMOTE CONTR...

Страница 21: ...puts processing Delay Parametric EQ Graphic EQ independent for every amp out and aux out Limiters independent for every amp out Smart VersaPower management Others Preset management Internal matrix pri...

Страница 22: ...ge humidity 5 85 RH non condensing Installation options Rack 19 installation desktop Included accessories Universal Main cords Euroblock Connectors inputs outputs Desktop feet rack 19 installation har...

Страница 23: ...23 PACKAGE CONTENTS FEATURES INSTALL CONNECT TECHNICAL DATA PANEL FUNCTIONS START UP OPERATION PRECAUTIONS T O C...

Страница 24: ...on tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your...

Отзывы: