12 Technical Data WRG 3010 E
12.1 Electrical data
WRG 3010 E
SIOX Extension Module
Supply voltage
230 V AC, 200 V AC ... 265 V AC, 50/60 Hz
24 V DC / 9 V DC
supply via basic construction
Rated power
24 VA
3.1 W
Leakage current over PE
(protective earth)
max 1 mA
Rated
surge voltage
2.5 kV for overvoltage category II
4.0 kV for overvoltage category III
Digital inputs
23 x 230 V AC, floating output
12 x 230 V AC, floating output
Relay outputs
6 x normally open contact, 250 V AC, floating output, min
10 mA
Load type: ohmic: max. 6 A, inductive: max. 3 A, cos phi
= 0.4
4 x changeover contact, 250 V AC, floating output, min
10 mA
Load type: ohmic: max. 6 A, inductive: max. 3 A, cos phi
= 0.4
4 x normally open contact, 250 V AC,
floating output, min 10 mA
Load type: ohmic: max. 6 A, inductive:
max. 3 A, cos phi = 0.4
4 x changeover contact, 250 V AC, floating
output, min 10 mA
Load type: ohmic: max. 6 A, inductive:
max. 3 A, cos phi = 0.4
Manual control switch
The base module as well as the extension modules have manual control switches so that the
regulation can be manually overridden in emergency operation, see chapter
Analogue inputs
1)
13 x Pt1000 2-wire temperature sensor
2 x 4-wire Pt1000 temperature sensor
7 x analogue input 4..20 mA / 0..10 V
--
Analogue outputs
1)
4 x 0..10 V (4..20 mA)
0..10 V (load min. 1 kOhm)/4..20 mA (resistance max.
800 Ohm)
--
Real-time clock
With power reserve and lithium cell (for details, see
""Transport and storage")
Accuracy: typical 12 minutes per year at 25 °C
-
Field bus interface
CAN bus, floating output
-
Data ports
1x data interface for SIOX
Internal interface to the basic construction
DANGER
Warning about dangerous electrical voltage! Danger to life - Danger of electric shock!
Overvoltage category III (test voltage 4.0 kV) / contamination degree 2:
All connections of the
device provided for operation with 230 V AC supply voltage
must
be wired with the same phase
conductor. 400 V AC between neighbouring connection terminals is
not
permitted!
Overvoltage category II (test voltage 2.5 kV) / contamination degree 2
or
overvoltage category II (test voltage 2.5 kV) / contamination degree 1:
Different phase conductors
may be used. 400 V AC between neighbouring connection terminals is permitted!
Содержание WRG 3010 E
Страница 70: ...Firmware V1 4 20 05 2021 70 113 7 1 Connections for 230 V AC top Basic Module SIOX Extension Module...
Страница 78: ...Firmware V1 4 20 05 2021 78 113 7 2 Connections for Protective Extra Low Voltage bottom...
Страница 84: ...Firmware V1 4 20 05 2021 84 113 7 3 Connections for Interfaces on the side Basic Module SIOX Extension Module...
Страница 103: ...Firmware V1 4 20 05 2021 103 113...