Operation of VS 300
82
Doku-Version 2.05 - Firmware 2.10 - 15. September 2017
Other functions of control keys
Simultaneously pressing the
↑
and
↓
keys at any operating level, except while entering values (flashing display),
actuates status display to indicate additional status information by the upper (8/9/10/11) and lower segments
(12/13/14/15) on the display. The left segments (8/10/12/14) on the LED display relate to Control Loop 1, the right
segments (9/11/13/15) to Control Loop 2.
At the same time relay/control stages indicators (3) are switched so that the status LEDs for the compressor or
condenser relays of Control Loop 1 continue to light normally and those of Control Loop 2 flash.
This allows identification of the relay/control stages assigned to the separate control loops for differentiation of
the relay/control stages of the two loops (normally compressor and condenser contro).
E
S
C
RE
S
ET
1
2
3
4
1
2
5
6
8
9
1
0
11
12
7
S
tatus
1
2
O
FF
Z
N
R
.
51203
51
330
/
/
O
FF
(10)
(11)
(1
4
)
(3)
(
8
)
(
9
)
(12)
(13) (15)
Example: The illustration shows the controller performing fast unload on Control Loop 1 (14) and working with
the second (nighttime) setpoint (10/11) (in both control loops). The status LEDs 1-4 (3) assigned to Control Loop
1 light normally, the status LEDs 5-6 (3) for Control Loop 2 are flashing. Pressing the ESC/RESET or
↵
key re
turns to basic display mode from any menu.
For additional convenience the
↑
and
↓
keys incorporate an accelerated auto-repeat function when pressed and
held down, enabling rapid scrolling and selection of parameter numbers or setpoints.
7.2
First start – Loading default values
Simultaneously pressing and holding the ESC/RESET,
↑
and
↓
keys on powering up the
controller initiates first
start, which loads the default settings. The default settings can also be loaded by means of a parameter (see
section 7 Parameter List and Menu Structure).
At first startup, the default settings for all parameters are loaded and all archives, messages/alarms
and operating data (e.g. run times, starts, activity) are deleted!
7.3
Menu and operating structure of VS 300
1
2
B
as
i
c d
i
sp
l
ay mode
S
e
l
ect
i
on of parameter
l
i
sts
S
e
l
ect
i
on of parameter
Parameter
i
ndex
Parameter sett
i
ng (f
l
ash
i
ng)
E
S
C
RE
S
ET
Parameter sett
i
ng
S
e
l
ect
i
on of
S
e
l
ect
i
on of
S
e
l
ect
i
on of
E
S
C
RE
S
ET
E
S
C
RE
S
ET
E
S
C
RE
S
ET
E
xamp
l
e:
Conf
i
rm entry
Z
N
R
.
51
203
5
6
030
E
0
Содержание VS 300
Страница 8: ...vi Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 18: ...System Design of VS 300 10 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 22: ...Application of VS 300 14 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 158: ...Parameter List and Menu Structure of VS 300 150 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 160: ...Decommissioning and disposal 152 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 166: ...Alarms and Messages of VS 300 158 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 170: ...162 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Страница 172: ...Order No s and accessories of VS 300 164 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...