KGL Operating Manual – UA 412 S
2019-01-14
/
101 122
KÜHLUNG 1 Pos: XXXXX
Hysteresis R4 xxx K
Display setpoint hysteresis return air temperature
Compressor
Display current OFF / ON state of the enable of all compressors terminals 35/36/38
Verd.Drehzahl 0%
Speed of the compressor
Compressor 1
Display current OFF / ON state of the compressor 1 terminals 25/26/28
Compressor 2
Display current OFF / ON state of the compressor 2 terminals 53/54
Compressor 3
Display current OFF / ON state of the compressor 3 terminals 63/64
Compressor 4
Display current OFF / ON state of the compressor 4 terminals 43/44
Dauerl.überw. OFF
Display current ON / OFF state of the continuous monitoring
Status Licht AUS
Display current ON / OFF state of the case lighting terminals 81/82
Menu 1-3 Defrost
ABTAUUNG 1 Pos: XXXXX
Counting rate X
Display counting rate
Defrost counter X
Display defrost counter
Abtauung XXX
Display current ON / OFF state of the defrost
Temperat. R1.1 XXX °C
Display current evaporator defrost end temperature terminals Z31 / Z32
Temperat. R1.2 XXX °C
Display current evaporator defrost end temperature terminals Z51 / Z52
Abtauendtemp XXX °C
Display setpoint defrost end temperature for comparison
Wartezeit XX m
Display setpoint wait time
Abtropfzeit XX m
Display setpoint drip time
letzte Abt. XX hh:mm
Display time (date, time) of the last started defrost
Menu 1-4
Not applicable for this controller type.
Menu 1-5 Alarm
ALARM Pos: XXXXX
Alarm relay XXX
Display current ON / OFF state of the output alarm terminals 15/16/18
Sicherheitsk.
Display current ON / OFF state of the input terminals D41/D42
Soll Übertemp1 XX °C
Display setpoint overtemperature
Soll Untertmp1 XX K
Display setpoint low temperature
Menu 1-6 Frame heater
RAHMEN XXXXX
Frame heater xxx
Display current ON / OFF state of the frame heater output terminals 91/92
Einschaltdauer xxx %
Display current run time of the frame heater
Feuchte XXX%
Display current room humidity (transmitted via CAN nus from the VS using the installed humidity sensor)
Raum-Temp xx °C
Display current room temperature (transmitted via CAN nus from the VS using the installed room temperature sensor)
9.2.3 Menu 2 Setpoints
SOLLWERTE POS: XXXXX
1 Cooling
Continue to menu 2-1
2 Defrost
Continue to menu 2-2