18 / 97
1.4.4
Status information in normal operation
After the start of the firmware, the controller changes to normal operation.
The single segments of the 7-segment indicator are assigned to a system task each. The
brightness of the various segments corresponds to the computing load of the single tasks
in the system.
The assignment is as follows:
Abbildung 2:
a
b
c
d
e
f
g
h
Figure 2:
7-Segment indicator
Tabelle 10:
Table 10:
Status information in normal operation, ENC66
Segment
Meaning
a
PLC (PLC program)
b
SRV (Services)
c
AXE (fine interpolator)
d
ZST (central controller)
e
INT (interpreter)
f
POS (interpolator)
g
NET (Ethernet communication)
h (dot)
Pulses in the rhythm of interpolator
(freq=1/MK_DELTAT [Hz])