background image

Echoflex Installation Guide

Magnetic Contact Sensor

Magnetic Contact Sensor (MC-31)

 Page 8 of 12

Echoflex

Operating Mode

The Operating Mode determines what type of event will trigger the MC-31 
to send a message. Minimizing transmissions conserves battery power, 
which may be a consideration in high-activity installations. 

1. Press and hold the 

[Teach]

 button until the white LED blinks twice.

2. Press and release the 

[Teach] 

button to cycle through the menu of 

color LEDs and stop when the red LED double-blinks.

3. Press and hold the 

[Teach]

 button until the white LED blinks twice to 

select Operating Mode. 

The red LED blink code displays the current setting. Press and release 
the 

[Teach]

 button to navigate the options. 

4. Press and hold the 

[Teach]

 button until the white LED blinks twice 

when the target indication displays. The MC-31 saves the setting and 
then restarts. 

The Operating Mode does not affect transmission of the configured 
heartbeat message. The two transmission settings are independent. 

To exit before time-out, press and hold the 

[Teach]

 button until the white 

LED blinks twice. 

Indication

Setting

Behavior

1 red blink

Every open or 
close event 
(default)

Sends 

Contact Open

 message 

when the contact goes from 
closed to open. Sends 

Contact 

Closed

 message when contact 

goes from open to closed

2 red blinks

Open events only

Sends 

Contact Open

 messages

3 red blinks

Close events only

Sends 

Contact Closed

 messages

Содержание MC-31

Страница 1: ...ity applications that require control to power a room or setback temperature control devices The MC 31incorporates features that assist the installer to position the device without the need for signal...

Страница 2: ...ne of the two slots at the side and gently pry to remove the sensor from the mounting plate 2 Mount the mounting plate using two 6 screws 3 Snap the sensor back into place Mount the Magnet Orienting t...

Страница 3: ...refer to the related product documentation 2 Press the Teach button on the sensor once to send a message The blue LED blinks to confirm a successful transmission 3 Deactivate Link mode on the controll...

Страница 4: ...he Teach button and color LEDs are used to navigate the Tests and Settings Menu The intervals between blinks make it easy to distinguish between single double and triple blinks Exit and Start Over gre...

Страница 5: ...Teach button until the white LED blinks twice 2 Press and release the Teach button to cycle through the menu of color LEDs and stop when the blue LED blinks once 3 Press and hold the Teach button unti...

Страница 6: ...operation a green LED blinks to indicate a contact open event and a red LED blinks to indicate a contact close event The LED Display setting controls whether the operating mode LEDs are enabled or dis...

Страница 7: ...ice 2 Press and release the Teach button to cycle through the menu of color LEDs and stop when the blue LED double blinks 3 Press and hold the Teach button until the white LED blinks twice to select E...

Страница 8: ...LED blink code displays the current setting Press and release the Teach button to navigate the options 4 Press and hold the Teach button until the white LED blinks twice when the target indication di...

Страница 9: ...the green LED triple blinks 3 Press and hold the Teach button until the white LED blinks twice to select Heartbeat Messaging The green LED blink code displays the current setting Press and release the...

Страница 10: ...le through the menu of color LEDs and stop when the blue LED triple blinks 3 Press and hold the Teach button until the white LED blinks twice to select Energy Status Messaging The blue LED blink code...

Страница 11: ...3 Press and hold the Teach button until the white LED blinks twice to select Redundant Messaging The red LED blink code displays the current setting Press and release the Teach button to navigate the...

Страница 12: ...anual may cause harmful interference to radio communications Any modifications or changes to this product not expressly approved by Electronic Theatre Controls Inc could void the user s authority to o...

Отзывы: