6
C
HARGING
S
TATION
I
NSTALLATION
P
ROCEDURE
14 AWG AC W
IRE
I
NSTALLATION
4)
Loosen the surge protector(s) terminal screws,
insert the ends of the wires into the surge
protector(s) at the locations shown, securely
tighten the terminal screws.
5)
Use an adjustable wrench or slip
‐
joint pliers to
securely tighten the cord grips.
14 AWG AC Wire Installation
1)
Pull the wires through the conduit and the
connector. Place the seal on the threaded side of
the connector.
2)
Place the connector into the input panel.
Assemble the nut (from inside of panel) onto the
connector. Allow 15.7 in. (400 mm) of wire on
the inside of the enclosure top.
1 – Peripheral wire
2 – Surge protector
3 – Power wires (pre
‐
assembled to surge protector(s)
1
2
3
1 – 14 AWG AC wires
2 – Liquid
‐
tight conduit
3 – Conduit connector
4 – Seal
1 – Conduit connector
2 – Nut
1
2
3
4
15.7 in.
;ϰϬϬŵŵͿ
1
2
1