8 Orientation errors
User Manual
194
Error
Modules
Error. File doesn't exist.
Point-to-Point,
Orthophoto, 3D
Photomodelling
This error is produced if, during orientation processing, the user moves or deletes a file from
the project or calibration directory.
Error
Modules
Cannot determine internal calibration.
Point-to-Point,
Orthophoto, 3D
Photomodelling
It is possible that you do not have calibration loaded correctly for the cameras you are using.
Error
Modules
Error. Orientation failure. Please, check image
…
Point-to-Point,
Orthophoto, 3D
Photomodelling
This error indicates that orientation processing has failed. The fault could have arisen
between the image mentioned and its adjacent images. It is recommended you take the
photos with more overlap, be sure they are well-focused and
don’t stand
too far away.
Error
Modules
Error. Please, not enough images.
Point-to-Point,
Orthophoto, 3D
Photomodelling
This error can arise if files are manually moved (like the images which are being used) while
the process is being undertaken.
Error
Modules
Error. Please, not enough common points.
Point-to-Point,
Orthophoto, 3D
Photomodelling
This error indicates that there are not enough common points between adjacent images to
carry out the process. It is recommended you take the photos with more overlap, be sure they
are well-focused and
don’t stand
too far away.
Error
Modules
Error. Please, there isn't Metadata/Exif in the images.
Point-to-Point,
Orthophoto, 3D
Photomodelling
The processed images do not have metadata. Check that EyesMap has not loaded images
processed with an external application whose metadata could have been modified.
Содержание eyesmap
Страница 1: ...USER MANUAL EYESMAP Version 1 0 Revision A June 2015...
Страница 9: ...2 Technical Specifications In this chapter we shall see Tablet Cameras Depth Sensor GPS IMU 2...
Страница 108: ...6 Viewers In this chapter we shall see MeshLab Touch Filters o Remove Outliers o Create Mesh o Clean Noise 6...
Страница 118: ...7 Practical cases User Manual 118 Medium Object...
Страница 119: ...7 Practical cases User Manual 119 Small Object...
Страница 120: ...7 Practical cases User Manual 120 7 1 1 2 Photo Development and Management...
Страница 121: ...7 Practical cases User Manual 121 Small Objects...
Страница 126: ...7 Practical cases User Manual 126 9 Orientation Points...
Страница 129: ...7 Practical cases User Manual 129 Click on Confirm...
Страница 130: ...7 Practical cases User Manual 130 The distance of the stereoTarget will be saved Click on Next...
Страница 134: ...7 Practical cases User Manual 134...
Страница 191: ...7 Practical cases User Manual 191...