Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
17
4.2.1.10 Equipment triad information
Operation
al code
Parameter
Request
0x09
None
Respond
0x09
Setup triad information
Example
Request
:
1C C0 09 DATA[26]
Respond
:
1D 40 09 DATA[26]
Note
:
This instruction be for E104-BT12SP-N configuration operation only
DATA[0`3] : pocet_id
DATA[4`9] : pocet_mac
DATA[10-26] : pocet_sec
The application method for this triad and the instruction usage method are shown in the "Apply
Triad to Ali and Set Up Device Information " document
4.2.1.12 Set LPN to Time Out and Return to Sleep
Operation
al code
Parameter
Request
0x0B
None
Respond
0x0B
Set time-out sleepout.
Example
Request
:
04 C0 0B TIME
Respond
:
05 40 0B TIME
Note
:
Default 5000 ms
This instruction be for e104-BT12SP-L configuration operation only
TIME:16-cimal segment mode
Column: Set 5000 ms, convert 5000 to 16-digit value 1388. When you set it, you need to write
8813.
04 C0 0B 8813
4.2.1.13 Timeout after Reading LPN External Wake-up
Operation
al code
Parameter
Request
0x0C
None
Respond
0x0C
Set time-out sleepout.
Example
Request
:
04 C0 0C TIME
Respond
:
05 40 0C TIME
Note
:
This instruction be for E104-BT12SP-L configuration operation only
TIME:16-cimal segment mode