NB1A1
16 Serial Server User Manual
Страница 1: ...Copyright 2012 2023 NB1A1 16 Serial Server User Manual...
Страница 2: ...er 4 Basic function 16 4 1 Mapping between Channels and serial ports 16 4 2 Local network parameter 16 4 2 1 Local IP address 16 4 2 2 DNS Domain name resolution 17 4 2 3 Disconnection and reconnectio...
Страница 3: ...logy Co Ltd NB1A1User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 5 4 4 Storage Gateway 28 5 4 5 Configurable gateway 29 5 4 6 Upload Automatically 30 5 5 Firmware upgrade 31...
Страница 4: ...binets and other industries 1 1 Features Industrial design is stable and reliable port isolation protection design 16 independent RS485 ports are supported Support a variety of Modbus gateway modes mu...
Страница 5: ...apter A network cable One USB to RS485 converter The following figure shows the hardware devices to be prepared Computer Net cable NB1A1 DC 12V1A USB to RS45 Conductor cables Note The Quick Start show...
Страница 6: ...Connect hardware 1 Connect serial port server network port and computer network port with network cable 2 use the USB to RS485 converter to connect the USB port of the computer and the RS485 interfac...
Страница 7: ...er using the default parameters of the serial server Open the configuration software click Search device select the device and check the following parameters Change the computer IP address as follows...
Страница 8: ...cessful the user can try to close the firewall of the computer and try again as shown in the following figure 2 3 3 Open the serial debugging assistant Start the XCOM V2 6 software select the correct...
Страница 9: ...23 Chengdu Ebyte Electronic Technology Co Ltd 6 2 3 4 Opening the Network Assistant Open the Network assistant software select the TCP Client mode set the remote IP address to 192 168 3 7 and the remo...
Страница 10: ...ce Description power terminal Dc 8 28 V the two interfaces cannot supply power at the same time Wire terminal 2pin phoenix terminal DC seat straight insert round hole outer diameter 5 5mm inner diamet...
Страница 11: ...default channel 1 Channel 16 8001 8016 Subnet mask Customizable default 255 255 255 0 Gateway Customizable default 192 168 3 1 Serial port packaging mechanism 512 Byte Serial baud rate 1200 460800 bps...
Страница 12: ...al input Do not supply power at the same time as the socket 2 DC8 28 V Positival terminal Dc 8 28 V 2 5 08mm Phoenix terminal input Do not supply power at the same time as the socket 3 DC IN Dc power...
Страница 13: ...erfaceA 3 81mmPhoenix terminal 22 RS485 12 B Channel12 RS485interfaceB 3 81mmPhoenix terminal 23 RS485 12 G Channel12 RS485interfaceG 3 81mmPhoenix terminal 24 RS485 11 A Channel11 RS485interfaceA 3 8...
Страница 14: ...85 2 G Channel2 RS485interfaceG 3 81mmPhoenix terminal 54 RS485 1 A Channel1 RS485interfaceA 3 81mmPhoenix terminal 55 RS485 1 B Channel1 RS485interfaceB 3 81mmPhoenix terminal 56 RS485 1 G Channel1 R...
Страница 15: ...s down Blinking The indicator blinks when the network or serial port is sending or receiving data Indicator light is on 1 The link is successfully connected 2 UDP server mode and after receiving the c...
Страница 16: ...rver mode and after receiving the client message 3 UDP client mode PORT10 Channel10 Status indicator If the indicator is off the link is down Blinking The indicator blinks when the network or serial p...
Страница 17: ...DP server mode and after receiving the client message 3 UDP client mode PORT15 Channel15 Status indicator If the indicator is off the link is down Blinking The indicator blinks when the network or ser...
Страница 18: ...Chengdu Ebyte Electronic Technology Co Ltd NB1A1User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 15 3 4 Size...
Страница 19: ...Channel2 COM2 PORT2 RS485 TCPS 8002 Channel3 COM3 PORT3 RS485 TCPS 8003 Channel4 COM4 PORT4 RS485 TCPS 8004 Channel5 COM5 PORT5 RS485 TCPS 8005 Channel6 COM6 PORT6 RS485 TCPS 8006 Channel7 COM7 PORT7...
Страница 20: ...nly needs to modify the routing device You do not need to configure this device How to configure DNS parameters 4 2 3 Disconnection and reconnection period The device periodically sends a reconnection...
Страница 21: ...rectly configured when the client is used When serving as a TCP client you are advised to set the local port to 0 that is the dynamic port 4 4 3 UDP Server In UDP Server mode the device does not verif...
Страница 22: ...cur 4 4 5 HTTP client This mode can realize the HTTP automatic packet grouping function providing two ways of GET and POST Customers can configure the URL Header and other parameters by themselves and...
Страница 23: ...ata can be configured 4 4 6 MQTT Client Support fast access to standard MQTT3 1 1 protocol servers OneNET Baidu Cloud Huawei Cloud user built server types etc and Alibaba Cloud servers support quality...
Страница 24: ...Device name User Password PrductKey Ali cloud parameters do not fill Release topic MQTT publishing topic address OneNET dynamic generation Subscribe to topics MQTT subscription subject address OneNET...
Страница 25: ...otherwise the client cannot establish a connection correctly the device is not listening to the port properly Random port connection can be quickly reestablished when the device disconnects the serve...
Страница 26: ...ce sends heartbeat messages to the serial port bus at the specified heartbeat interval 3 Network Port Mode The device sends heartbeat messages to the network port bus at the specified heartbeat interv...
Страница 27: ...to connect to the server only when sending messages If the connection is successful the device automatically disconnects if the serial port does not receive data or the network port does not send or...
Страница 28: ...n modbus data RTU TCP is discarded and not transmitted 5 4 2 Simple Protocol Conversion Modbus RTU data is converted to Modbus TCP data or Modbus TCP data is converted to Modbus RTU data and Ethernet...
Страница 29: ...User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 26 Software register reading and simulation configuration Poll menu select SetupRead Write Definition Slave Menu selection Se...
Страница 30: ...e supported and the simultaneous access of multiple hosts should pay attention to the matching of request interval and timeout time Otherwise the serial port transmission rate is much lower than the E...
Страница 31: ...d instruction storage time of the storage area according to requirements 1 As an optimization of multi host request performance storage gateway can only work in TCP server mode which improves the resp...
Страница 32: ...non stored instructions will directly operate the RTU device The frequently read instructions can be stored in the gateway in advance which can shorten the response time query the configured instruct...
Страница 33: ...poll the instructions stored in the instruction table and upload them to the server The feedback format Modbus RTU format or Modbus TCP format and the instruction polling interval 0 65535ms can be sel...
Страница 34: ...Chengdu Ebyte Electronic Technology Co Ltd NB1A1User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 31 5 5 Firmware upgrade...
Страница 35: ...012 2023 Chengdu Ebyte Electronic Technology Co Ltd 32 Users can upgrade the firmware of the device through network cables For details about how to upgrade the firmware see the upgrade package If the...
Страница 36: ...s to Chengdu Ebyte Electronic Technology Co LTD Revise History Version Revise date Revise description maintainer 1 0 2023 9 18 Initial version LYL About Us Sales hotline 4000 330 990 Company Tel 028 6...