Chengdu Ebyte Electronic Technology Co.,Ltd.
【
RS485
⇌
WiFi
】
NA611 User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
22
(2) Configure STA equipment:
Setting mode: AT+MODE=2,1,3
Set the target SSID: AT+STACON=E103-W06,2,12345678
Set connection method: AT+CONTYPE=1
Set the local port: AT+SVRPORTIP=4002 (note that the local port here is the remote port from the previous step)
Set the remote port remote IP: AT+SOCKET=0,4001,10.145.45.1 (the remote port IP here is the local port IP in the
previous step)
(3) Restart the device, wait for connection, and communicate.
Содержание NA611
Страница 1: ... RS485 WiFi NA611 NA611A ...