6.2 Broadcast Transmission (hexadecimal)
6.3 Broadcast address
Example: set the module A address to 0xFFFF and the channel to 0x04.
When module A acts as a transmitter (same mode, transparent transmission method), all receiving modules under
channel 0x04 can receive the data for the purpose of broadcasting.
6.4 Listener address
Example: set the module A address to 0xFFFF and the channel to 0x04.
When module A acts as a receiver, it can receive all the data under channel 0x04 for the purpose of listening.
6.5
Exception Work Status Log Printing Details
1.
The ERR indicator will blink according to the following table based on the specific abnormal operating status.
Abnormal
working
condition
Thresholds
for
determining
anomalous states
ERR indicator blinking condition
phase sequence
Supply voltage <11V
Blinks once in 500ms
overpressurization
Supply voltage >13V
1s blinks once
overheat (e.g. an
economy)
Module temperature > 120
°
C
Flashes once in 2s
Overpressure and
Supply voltage >13V and
Ever Bright