Chengdu Ebyte Electronic Technology Co.,Ltd
E79-900DM2005S User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd
7
18
DIO_16
Input/Output
Configurable universal IO, JYAG Port (see CC1352P1F3RGZ Manual)
19
DIO_17
Input/Output
Configurable universal IO, JYAG Port (see CC1352P1F3RGZ Manual)
20
DIO_18
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
21
DIO_19
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
22
DIO_20
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
23
DIO_21
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
24
DIO_22
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
25
RESET_N
Input
Reset Pin
26
GND
Input/Output
Ground wire, connected to the power reference ground
27
GND
Input/Output
Ground wire, connected to the power reference ground
28
DIO_23
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
29
DIO_28
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
30
DIO_27
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
31
DIO_24
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
32
DIO_25
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
33
DIO_26
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
34
DIO_29
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
35
DIO_30
Input/Output
Configurable universal IO Port (see CC1352P1F3RGZ Manual)
36
VCC
Input/Output
Module power supply positive reference voltage, voltage range 1.8 ~ 3.8V
37
GND
Input/Output
Ground wire, connected to the power reference ground
4. Programming and Testing:
No
Name
Notice
1
Burning
Program
The module is a SOC module, comes with a GPIO port, please download
program by XDS100 downloader.
2
Test Board
Not available from Ebyte
5. User Guide
5.1 Notice for Hardware
It is recommended to use DC stabilized power supply. The power supply ripple factor should be as small as possible, and
the module should be reliably grounded.
Please ensure that the positive and negative poles of the power supply are properly connected. If the reverse connection is
made, the module may be permanently damaged.
Please ensure the power supply voltage is within the working voltage range. If the maximum voltage is exceeded, the
module will be permanently damaged.
Please check the stability of the power supply, and the voltage cannot be fluctuated frequently;
When designing the power supply circuit for the module, it is recommended to reserve more than 30% of the margin to