
Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright © 2012–2022 , Chengdu Ebyte Electronic Technology Co., Ltd.
44
send )
mand
OK
set comman
d
AT+CADR=<value>
OK
Parameter D
escription
<value>: as follows.
ADR enable control, the factory value is 1
0 - ADR disabled
1 - ADR enabled
Return valu
e descriptio
n
Example
AT+CADR=1
OK
Precautions
It needs to be set before sending data. ADR is enabled by defaul
t.
command chara
cters
Command t
ype
command format
response
CRXP
( Set receive w
indow paramete
rs )
test comma
nd
AT+CRXP=?
+CRXP: " RX1DRoffest " , " RX2
DataRate " , " RX2Frequency
"
OK
query com
mand
AT+CRXP?
+CRXP:<RX1DRoffest>,<RX2DataRa
te>,<RX2Frequency>
OK
set comman
d
AT+CRXP=<RX1DRoffest
>,<RX2DataRate>,<RX2Fre
quency>
OK
Parameter D
escription
<RX1DRoffest>,<RX2DataRate>,<RX2Frequency> See LoRaWAN
protocol for details.
Return valu