Parameter D
escription
<value>: Enable Control
0 for Link Check – Disable Link Check
1 - Execute Link Check once
2 - The module automatically carries the linkcheck command in e
ach upstream data packet.
Return OK, the setting is successful.
If X1=1, after waiting for a period of time, the second response
message will be returned, the format is as follows:
+CLINKCHECK: Y0, Y1, Y2, Y3, Y4
YO represents the Link Check result:
0 - Indicates that this Link Check was executed successfully
Non-0 - Indicates that this Link Check failed to execute
Y1 is DemodMargin
Y2 is NbGateways
Y3 is the RSSI of this downlink
Y4 is the SNR of this downlink
Return valu
e descriptio
n
Example
AT+CLINKCHECK=1
OK
+ CLINKCHECK: 0, 0, 1, -68, 8
Precautions
Need to set before sending data
command chara
cters
Command t
ype
command format
response
CADR
( Set the numb
er of times to
test comma
nd
AT+CADR=?
+CADR:"value"
OK
query com AT+CADR?
+CADR:<value>