Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright © 2012–2022 , Chengdu Ebyte Electronic Technology Co., Ltd.
38
command chara
cters
Command t
ype
command format
response
CAPPPORT
( Set the uplin
k data port nu
mber )
test comma
nd
AT+CAPPPORT=?
+CAPPPORT: " value "
OK
query com
mand
AT+CAPPPORT?
+CAPPPORT:<value>
OK
set comman
d
AT+CAPPPORT=<value>
OK
Parameter D
escription
<value>: as follows:
The port used, the data format is decimal, and the factory value i
s 10.
Value range: 1~223;
Note: Port: 0x00 is the LoRaWAN MAC command
Return valu
e descriptio
n
Example
AT+CAPPPORT=10
OK
Precautions
Need to set before sending data
command chara
cters
Command t
ype
command format
response
CDATARATE
( Set the com
munication rate
)
test comma
nd
AT+CDATARATE=?
+CDATARATE: " value "
OK
query com
mand
AT+CDATARATE?
+CDATARATE:<value>
OK
set comman
d
AT+CDATARATE =<value
>
OK
Parameter D
escription
<value>: as follows:
Rate value, the factory value is 3, the value range:
0 - SF12, BW125
1 - SF11, BW125
Return valu
e descriptio
n