7. FAQ

7.1 Communication range is too short

The communication distance will be affected when obstacle exists.

Data lose rate will be affected by temperature, humidity and co-channel interference.

The ground will absorb and reflect wireless radio wave, so the performance will be poor when testing near ground.

Sea water has great ability in absorbing wireless radio wave, so performance will be poor when testing near the sea.

The signal will be affected when the antenna is near metal object or put in a metal case.

Power register was set incorrectly, air data rate is set as too high (the higher the air data rate, the shorter the
distance).

The power supply low voltage is lower than recommended under room temperature. The lower the voltage is, the
smaller the transmitting power is.

Due to antenna quality or poor matching between antenna and module.

7.2 Module is easy to damage

Please check the power supply to ensure that it is within the recommended value. If it exceeds the maximum value,
the module will be permanently damaged;

Please check the stability of power source, the voltage cannot fluctuate too much.

Please make sure anti-static measures are taken when installing and using, high frequency devices have electrostatic
susceptibility.

Please ensure the humidity is within limited range, some parts are sensitive to humidity.

Please avoid using modules under too high or too low temperature.

8. Important statement

1. EBYTE reserves the right of final interpretation and modification of all contents in this manual.
2. As the hardware and software of the product continue to improve, this manual may be subject to change without
further notice, and the final version of the manual shall prevail.
3. Users of this product need to pay attention to the product updates on our official website, in order to get the latest
information of this product in time.

Содержание E78-470LN22S

Страница 1: ...Chengdu Ebyte Electronic Technology Co Ltd E78 900M22S User manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd ASR6501Wireless Module E78 470LN22S...

Страница 2: ...2 Parameter Description 3 2 Terms and definitions 5 3 Mechanical properties 6 3 1 E78 470LN22S Dimensions 6 3 2 Pin definition 6 3 3 Recommended connection diagram 7 4 LoraWan application model diagr...

Страница 3: ...duction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided...

Страница 4: ...use the launch time is extremely short the total energy consumed may be smaller When the customer uses an external antenna the impedance matching degree between the antenna and the module at different...

Страница 5: ...gdu Ebyte Electronic Technology Co Ltd E78 470LN22S User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 4 emissions for a number of reasons reduces the efficiency of the interna...

Страница 6: ...mission of the server in a short time after the terminal uplink transmission The downstream transmission of the server at any other time has to wait for the next uplink of the terminal Two way transmi...

Страница 7: ...y range 2 5 3 7v external ceramic filter capacitor is recommended 3 SETB Low power wake up pin 4 DIO1 Input output NC reserved pin 5 BUSY Input output NC reserved pin 6 I2C_SDA Input output NC reserve...

Страница 8: ...UART TX pin 22 SWD_DATA Input output SWD Data pin 23 SWD_CLK Input output SWD Clock pin 24 GND Ground wire connected to power reference ground 25 SPI_MISO Input output SPI MISO test point internally...

Страница 9: ...tem consists of node gateway Lora NetWork Server application server the node is generally designed by LORA chip the gateway is designed by SX1301 provided by semtech Lora NetWork Server now has open s...

Страница 10: ...gy Co Ltd 9 5 Access demo The demonstration kit is E78 470LN22S as a node E890 as a gateway to access the free TTN TheThingsNetwork test server for communication test node side OTAA access mode corres...

Страница 11: ...Technology Co Ltd E78 470LN22S User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 10 The access example in the transparent transmission mode is as follows App server receives...

Страница 12: ...Ltd E78 470LN22S User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 11 Note For the TTN creation device and corresponding configuration process please refer to LORAWAN Node Gat...

Страница 13: ...when entering the network CJOINMODE Set the read join mode OTAA ABP CDEVEUI Set to read DevEUI OTAA when entering the network CAPPEUI Set to read AppEUI OTAA when entering the network CAPPKEY Set to...

Страница 14: ...Restore default configuration IREBOOT System reset CLPM System low power settings ECHO Serial command echo configuration Command character Command Type Command Format response CGMI Read the manufactu...

Страница 15: ...T CGSN CGSN sn OK Parameter Description sn Product serial number identifier Return value description Example AT CGSN CGSN 0539349E00032523 OK Precautions Command character Command Type Command Format...

Страница 16: ...UI CDEVEUI value OK Setting command AT CDEVEUI mode OK Parameter Description mode Node DevEUI Return value description Example AT CDEVEUI CDEVEUI AABBCCDD00112233 OK Precautions Set or read DevEUI ret...

Страница 17: ...character Command Type Command Format response CDEVADDR Set DevAddr Test command AT CDEVADDR CDEVADDR DevAddr length is 8 Device address of ABP mode Query command AT CDEVADDR CDEVADDR value OK Settin...

Страница 18: ...n Y1Y2 Y16 hexadecimal format and take 16 bytes CFREQBANDM ASK Set the band mask Command Type Command Format response Test command AT CFREQBANDMASK CFREQBANDMASK mask OK Query command AT CFREQBANDMASK...

Страница 19: ...T CWORKMODE mode OK Parameter Description mode 2 Normal operation mode Return value description Example AT CWORKMODE 2 OK Precautions It needs to be set before joining and the default is normal workin...

Страница 20: ...K Example Query the current status of the device Command character Command Type Command Format response CJOIN Set Join Test command AT CJOIN CJOIN ParaTag1 ParaTag2 Para Tag4 OK Query command AT CJOIN...

Страница 21: ...ngth Pay load OK Setting command AT DTRX confirm nbtrials Length Payload OK SEND TX_LEN OK SENT TX_CN OK SEND TX_LEN OK SENT TX_CNT OK RECV TYPE PORT LEN DATA ERR SEND ERR_NUM ERR SENT TX_CNT Paramete...

Страница 22: ...ication is busy sending request failed 2 The data length exceeds the current transmittable length and only the MAC command is sent ERR SENT TX_CNT indicates that the data transmission failed the maxim...

Страница 23: ...H MODE Transparent transmission mode Test command AT CPASSTHOUGHMODE CPASSTHOUGHMODE mode confi rm nbtrials Set command AT CPASSTHOUGHMODE mode confirm nbtrials OK Parameter Description When mode is 1...

Страница 24: ...transparent transmission mode It needs to wait for the server to respond or send timeout before sending hex 2B 2B 2B to exit the transparent transmission mode 3 Before entering the transparent transm...

Страница 25: ...Format response CDATARATE Set the communication rate Test command AT CDATARATE CDATARATE value OK Query command AT CDATARATE CDATARATE value OK Setting command AT CDATARATE value OK Parameter Descript...

Страница 26: ...RIALS CNBTRIALS MType value OK Setting command AT CNBTRIALS MType value OK Parameter Description MType 0 unconfirm 1 confirm value the maximum number of times to send value range 1 15 Return value des...

Страница 27: ...CTXP Set the transmit power Test command AT CTXP CTXP value OK Query command AT CTXP CTXP value OK Setting command AT CTXP value OK Parameter Description is the transmission power size the factory val...

Страница 28: ...K CLINKCHECK 0 0 1 68 8 Precautions Need to set before sending data Command character Command Type Command Format response CADR Set send times Test command AT CADR CADR value OK Query command AT CADR...

Страница 29: ...n Example AT CRX1DELAY 2 OK Precautions Set how long the rx1 window will open after sending and set before sending data It is the protocol default value when not set Command character Command Type Com...

Страница 30: ...BOOT 1 OK Precautions After receiving the instruction the communication module will reply to OK and restart the communication module No further AT commands are received until the restart is complete C...

Страница 31: ...ruction echo command OK Setting command AT ECHO mode OK Parameter Description mode command echo 0 The instruction turns off the echo 1 The command turns on echo Return value description Example AT ECH...

Страница 32: ...ansmitting power is Due to antenna quality or poor matching between antenna and module 7 2 Module is easy to damage Please check the power supply to ensure that it is within the recommended value If i...

Страница 33: ...tion optimization Linson 1 4 2021 3 31 Add transparent transmission mode Description optimization Glhuar 1 5 2021 4 16 Modification instructions on CRESTORE command Gluhar 10 About us Technical suppor...

Отзывы: