before sending data.   

       Long  address transmission. When configured to long  address transmission, the user must spe cify  the long address 

before sending data. 

 

6.2.

 

Normal node 

If the user configures the operating mode 4,

M0=0,M1=1

or  the user configures the operating mode as 1, the modem 

works in the normal  node mode.  In the normal  node mode, the data can be received and se nt in real time.  It is suitable for 
application with low power consumption but high real-time  requirement. 

6.3.

 

Dormant  node 

If  the user configures the operating mode  as 4,  M0=1,  M1=0,  or  the user configures the operating mode  as 2,  the 

modem  works  in the dormant node mode.  the device request if there is data transmitted  by coordinator according to the 
user-configured  sleep  period,  The  non-broadcast data  sent  by  the  coordinator  will  be  temporarily  stored  inside  the 
coordinator. The device is in low power consumption during the sleep period. If the sleep node wants to send data actively, 
the user should send no more  than two bytes to wake  up the device. After the byte data is used to wake  up the device and 
the wake-up byte is sent, the user needs to wait for more  than 100ms  to send the real data. After the wake-up byte is sent, 
the user needs to wait for 100ms  to send the real  data and the wake-up data will  be discarded. After the device was waken  
up, the modem  will  open the serial port, receiving AT command,  if more  than 2 seconds, there is no data input, the modem 
will  close serial  port  and go  to sleep.  The  sleep node is  suitable  for  applications where  the user  requires  high  power 
consumption but does not require high real-time  data. 

 

6.4.

 

Configuration  Mode 

When M0=1,M1=1,the  device  will  switch to configuration  mode.  In  the this mode,  the serial  port parameters  are: 

115200,  8N1,  and the average operating current is 2uA. In this mode,  the modem  cannot send and receive data. When the 
external AT instruction is configured, needs the serial port to send no more than two bytes data to wake up the device. A fter 
the wake-up  byte is sent, the user needs to wait for 100ms  to send the real data and the wake -up data will  be discarded. 
After the device was waken up, the modem  will  open the serial port, receiving AT command,  if more  than 2 seconds, there 
is no data input, the modem  will  close serial  port and go to sleep. 

 

6.5.

 

Mode switching   

No 

Remarks 

The user can decide  the operating mode by the combination of M1 and M0 

In any work mode, the user can configure  the operating mode through the AT command   

When M0=1,M1=1, the serial port parameters are 115200, 8N1(fixed) 

Содержание E70-DTU

Страница 1: ...Chengdu Ebyte Electronic Technology Co Ltd E70 DTU 433NW30 user manual E70 DTU 433NW30...

Страница 2: ...0 SERIES 5 3 FUNCTION DESCRIPTION 5 3 1 PIN DESCRIPTION 5 3 2 PIN DEFINITION 6 3 3 DIMENSION 7 4 FAQ 8 5 FIRMWARE TRANSMITTING MODE 8 5 1 TRANSPARENT TRANSMISSION 8 5 2 SHORT ADDRESS TRANSMISSION 8 6...

Страница 3: ...s wireless communication network applications Features Use AT command to configure parameters In the coordinator mode support broadcast transmission short address transmission and long address transmi...

Страница 4: ...ools This datasheet choosesserialport assistant netconfig_V1 3 Please download the software driver from Ebyte official website 1 2 1 Test procedure The device is mode 4 as default using the external h...

Страница 5: ...td 3 Use serial port assistant to change the mode of E70 DTU 433NW30 Enters into AT Command AT WMCFG Reading current operation mode AT WMCFG 0 Change to 0 mode coordinator mode AT RSTART Module restar...

Страница 6: ...t Introduction 2 1 Electrical Parameter No Parameter Name Description 1 Size 82 62 25mm 2 Weight 116g 2g 3 Working frequency 433MHz 4 Transmitting power 30dBm 5 Power supply 8 28V DC Note Higher than...

Страница 7: ...4 Operating current Transmitting 468mA 12V Receiving 24 2mA 12V 15 Operating temperature 40 85 Industrial grade 16 Operating humidity 10 90 17 Storage temperature 40 125 Industrial grade 2 2 E70 Serie...

Страница 8: ...n Function 1 RS232 RS232 interface 2 485_A RS 485 interface A 3 485_B RS 485 interface B 4 GND Ground 5 VCC Power supply DC8 28V 6 PWR Power Indicator 7 LINK Network successfully established indicator...

Страница 9: ...Chengdu Ebyte Electronic Technology Co Ltd E70 DTU 433NW30 user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 3 3 Dimension...

Страница 10: ...nable to read parameter Check whether the baud rate of the serial port is correct You can query in the configuration mode Into the network is too long During the network access process the node and th...

Страница 11: ...m works in the coordinator mode In the coordinatormode the coordinator can set up the network coordinator is the central node of the network there must be a coordinator in the network The coordinator...

Страница 12: ...nt the user needs to wait for more than 100ms to send the real data After the wake up byte is sent the userneeds to wait for 100ms to send the real data and the wake up data will be discarded After th...

Страница 13: ...mand mode AT EXIT Parameter Description Null Response Exit AT Mode Example AT EXIT Note AT commands are invalid after exiting AT command mode 3 AT HELP Help command AT HELP Parameter Description Null...

Страница 14: ...ffffffffffffff arebroadcast address Example AT TFICFG 0 8 AT TMCFG Setting Querying transport modeconfiguration reboot valid AT TMCFG Description Gets transport modeconfiguration Response TMCFG 0 AT T...

Страница 15: ...rameter Response UBCFG 7 AT UBCFG Value Description Value 0 7 0 1200 1 2400 2 4800 3 9600 4 19200 5 38400 6 57600 7 115200 Example AT UBCFG 7 13 AT UPCFG Setting Querying the device parity parameter r...

Страница 16: ...ency performance parameter Response TLCFG 0 AT TLCFG value Description Value 0 3 0 Low concurrency 1 Medium concurrency 2 High concurrency 3 Highest concurrency Example AT TLCFG 0 Note This parameter...

Страница 17: ...ion but the delay of receiving coordinator will be even higher Low power node cannot receive broadcast data which transmitted by the coordinator The systemwill be reset if the node is powered on for m...

Страница 18: ...1 20 2019 04 12 initial version Molly 1 00 2018 03 29 Initial version huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyt...

Отзывы: