Chengdu Ebyte Electronic Technology Co,;Ltd E70-433T30S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd 4
2. Specification and parameter
2.1 Limit parameter
Main parameter
Performance
Remarks
Min.
Max.
Power supply
(
V
)
0
5.5
Voltage over 3.8V will cause permanent
damage to module
Blocking power
(
dBm
)
-
10
Chances of burn is slim when modules
are used in short distance
Operating temperature
(
℃
)
-40
85
-
2.2 Operating parameter
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
2.6
5.0
5.5
≥3.3 V ensures output power
Communication level
(
V
)
-
3.3
-
For 5V TTL, it may be at risk of
burning down
Operating temperature
(
℃
)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
431
-
446.5
Support ISM band
Power
consumption
Transmitting current [mA]
-
530
-
Instant power consumption
Receiving current [mA]
-
14
-
-
Turn-off current [μA]
-
4.0
-
Software is shut down
Max Tx power
(
dBm
)
13.5
30.0
15.7
-
Receiving sensitivity
(
dBm
)
-107
-108
-109
Air data rate is 5kbps
Air data rate
(
bps
)
2.5k
2.5k
168k
Controlled via user’s programming
Main parameter
Description
Remark
Distance for reference
6000m
Test condition
:
clear and open area, antenna gain: 5dBi
,
antenna height: 2.5m
,
air data rate: 2.5kbps
TX length
Transmission mode specification
See transmission mode for details
Buffer
2048Byte
-
M odulation
GFSK
-
Communication interface
UART
-
Package
SM D
-
Connector
1.27mm
-
Size
24*38.5mm
-
Antenna
IPX/Stamp hole
50 ohm impedance