Chengdu Ebyte Electronic Technology Co,;Ltd
E70-433TxxSx user manual
Copyright ©2012–2023
,
Chengdu Ebyte Electronic Technology Co,;Ltd
4
Advanced Meter Reading Architecture(AMI)
;
Automotive industry applications.
2. Specification and parameter
2.1 Limit parameter
Main parameter
Performance
Remarks
Min.
Max.
Power supply
(
V
)
E70-900T30S
0
5.5
Voltage over 5.5V will cause permanent
damage to module
E70-900T14S/S2
0
3.8
Voltage over 3.8V will cause permanent
damage to module
Blocking power
(
dBm
)
-
10
Chances of burn is slim when modules
are used in short distance
Operating temperature
(
℃
)
-40
85
2.2 Operating parameter
E70-433T30S
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
2.6
5.0
5.5
≥5.0 V ensures output power
Communication level
(
V
)
3.3
For 5V TTL, it may be at risk of
burning down
Operating temperature
(
℃
)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
431
-
446.5
Support ISM band
Power
consumption
Transmitting current [mA]
530
Instant power consumption
Receiving current [mA]
14
Turn-off current [μA]
4.0
Software is shut down
Max Tx power
(
dBm
)
13.5
30.0
15.7
Receiving sensitivity
(
dBm
)
-107
-108
-109
Air data rate is 2.5kbps
Air data rate
(
bps
)
2.5k
2.5k
168k
Controlled via user’s programming
E70-433T14S/S2
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
2.2
3.3
3.8
≥3.3 V ensures output power
Communication level
(
V
)
-
3.3
-
For 5V TTL, it may be at risk of burning down