2.  Specification  and parameter 

2.1 2.1 Limit parameter 

Main parameter

 

 

Performance

 

Remarks 

Min.

 

Max.

 

Power supply

V

 

5.2 

Voltage  over 5.2V will cause permanent 

damage  to module 

Blocking  power

dBm

 

10 

Chances of burn is slim when modules 

are used in short distance 

Operating temperature

 

-40 

85 

 

 

2.2 Operating parameter 

Main parameter 

 

Performance 

Remark 

Min 

Typ. 

Max. 

Operating voltage

V

 

3.3 

5.0 

5.2 

≥5.0 V ensures output power 

Communication level

V

 

-

 

 

3.3 

-

 

 

For 5V TTL, it may be at risk of 

burning down   

Operating temperature

 

-40 

85 

Industrial design 

Operating frequency

MHz

 

425 

450.5 

Support ISM band 

Power 

consumptio

 

Transmitting current [mA] 

-

 

 

640 

-

 

 

Instant power consumption 

Receiving  current [mA] 

-

 

 

40 

-

 

 

Turn-off current [μA] 

-

 

 

-

 

 

Software is shut down 

Max Tx power

dBm

 

29.6 

30.0 

31.4 

-

 

 

Receiving  sensitivity

dBm

 

-108 

-109 

-110 

Air data rate is 64kbps 

Air data rate

bps

 

16k 

64k 

128k 

Controlled via user’s programming   

 

Main parameter 

Description 

Remark 

Distance for reference 

3000m 

Test condition

clear  and open area, antenna gain:  5dBi

antenna height:  2.5m

air data rate: 64kbps 

TX length 

1024 Byte 

Internal automatic time division  logic  subcontracting 

Buffer 

2048 Byte 

Internal Buffer 

M odulation 

GFSK 

Содержание E62-422T30D

Страница 1: ...E62 433T30D User Manual 433MHz 1W Wireless Module...

Страница 2: ...Indication of UART output 7 5 2 2 Indication of wireless transmitting 7 5 2 3 Configuration procedure of module 8 5 6 4 Notes for AUX 8 6 OPERATING MODE 9 6 2 TRANSMISSION MODE MODE 0 10 6 3CONFIGURE...

Страница 3: ...gy Co Ltd E62 433T30D user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 2 10 PRODUCTION GUIDANCE 16 11 E62 SERIES 16 12 ANTENNA RECOMMENDATION 17 13 PACKAGE FOR BATCH ORDER 18...

Страница 4: ...transmission operation and it achieve a very low latency communication link The module features FEC Forward Error Correction algorithm which ensure its high coding efficiency good correction performan...

Страница 5: ...voltage V 3 3 5 0 5 2 5 0 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 85 Industrial design Operating frequency MHz 425 450 5...

Страница 6: ...interface UART Package DIP Connector 2 54mm Size 37 60mm Antenna SMA K 50 ohm impedance 3 Size and pin definition No Name Direction Function 1 M0 Input weak pull up Work with M1 to decide 4 working m...

Страница 7: ...onnects to external RXD MCU PC input pin Can be configured as open drain or push pulloutput 5 AUX Output To indicate module s working status wakes up the external MCU During the procedure of self chec...

Страница 8: ...here are data that are not sent yet via wireless way or whether all wireless data has been sent through UART or whether the module is still in the process ofself check initialization 5 2 1 Indication...

Страница 9: ...UX outputs low level if none of the low level condition is met AUX outputs high level 2 When AUX outputs low level it means the module is busy cannot conduct operating mode checking Within 1ms since A...

Страница 10: ...through serial port it will start to work in new mode after thetransmitting finished Therefore the mode switch is only valid when AUX outputs 1 otherwiseit will delay 2 For example in mode 0 or mode...

Страница 11: ...ormat Illustration 1 C0 working parameters C0 5 bytes working parameters are sent in hexadecimal format 6 bytes in totaland must be send in succession Save the parameters when power down Type When M0...

Страница 12: ...el launch mode Baud rate Parity Transmitting power E62 433T30D 425 450 5MHz 1 10 64kbps 9600 8N1 1W 7 2 Reading operating parameters Instruction format Description C1 C1 C1 In parameter setting mode M...

Страница 13: ...ed for the occasion that need to change the operating parameters frequently such as C2 01 0A 1A 0A 44 No Item Description Notes 0 HEAD Fix 0xC0 or 0xC2 it means this frame data is control command Must...

Страница 14: ...tion parties The UART baud rate has nothing to do with wireless transmission parameters won t affect the wireless transmit receive features 0 is recommended The lower the air data rate the longer the...

Страница 15: ...is recommended After turn off FEC the actual data transmission rate increases while anti interference ability decreases Also the transmission distance is relatively short Both communication parties mu...

Страница 16: ...h large electromagnetic interference around the module that will greatly affect the performance It is recommended to keep them away from the module according to the strength ofthe interference If nece...

Страница 17: ...ensure the humidity is within limited range some parts are sensitive to humidity Please avoid using modules under too high or too low temperature 9 3 BER Bit Error Rate is high There are co channel si...

Страница 18: ...Flexible omnidirectional TX433 JWG 7 Rubber antenna 433M SMA J 2 5 75mm Flexible omnidirectional TX433 JK 20 Rubber antenna 433M SMA J 3 210mm Flexible omnidirectional TX433 JK 11 Rubber antenna 433M...

Страница 19: ...Chengdu Ebyte Electronic Technology Co Ltd E62 433T30D user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 18 13 Package for batch order...

Страница 20: ...al version huaa 1 10 2018 01 30 module name change huaa 1 20 2018 10 25 version updating huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank...

Отзывы: