background image

 

Chengdu Ebyte Electronic Technology Co,;Ltd                                                                                          E62-433T30D user manual 

 

Copyright ©2012–2019

Chengdu Ebyte Electronic Technology Co,;Ltd                                                                                                                               9

 

5.7 LOCK description 

 

6.Operating  mode 

Contents in below table are the introduction of input status of M1 & M0 and their corresponding mode:•  

Mode(0-3) 

M1 

M0 

Mode  introduction 

Remark 

Mode 0 

Transmitting 

UART and wireless channel  are open, 

transparent transmission is on. 

In this mode, module can be configured  as serial 

transmission (default) and fixed-length 

transmission. 

Mode 1 

Reserve 

Reserve 

Mode 2 

Command 

UART is open, wireless channel  is 

disabled, can be used for parameter-

setting. 

For parameter-setting 

Mode 3 

Sleep 

The module goes to sleep, and the serial 

port and module are closed. 

 

 

6.1 Mode switch 

No. 

Remarks 

The user can decide  the operating mode by the combination of M1 and M0. The two GPIO of MCU can be used to 

switch mode. After modifying M1 or M0, it will start to work in new mode 1 ms later if the module is free. If there are 

any serial data that are yet to finish wireless transmitting, it will start to work in new mode after the UART transmitting 

finished. After the module receives the wireless data & transmits the data through serial port, it will start to work in new 

mode after the transmitting finished. Therefore, the mode-switch is only valid when AUX outputs 1, otherwise it will 

delay. 

For example, in mode 0 or mode 1, if the user inputs massive data consecutively and switches operating mode at the 

same time, the mode-switch operation is invalid. New mode checking  can only be started after all the user’s data process 

completed. It is recommended  to check AUX pinout status and wait 2ms after AUX outputs high level before switching 

the mode. 

If the module switches from other modes to stand-by mode, it will work in stand-by mode only after all the remained 

data process completed. The feature can be used to save power consumption. For example,  when the transmitter works in 

mode 0, after the external  MCU transmits data “12345”, it can switch to sleep mode immediately without waiting the 

rising edge  of the AUX pin, also the user’s main MCU will go dormancy immediately. Then the module will transmit all 

1

 

Due to the characteristics of TDD and frequency modulation spread spectrum, the module can operate at the same time.

 

2

 

Lock is used to indicate the synchronization situation for both side (transmitter and receiver). When lock is high  level, 
synchronization completed, communication is available.  Otherwise when lock is low level, synchronization completed, 
communication  is unavailable  (data lost).

 

Содержание E62-422T30D

Страница 1: ...E62 433T30D User Manual 433MHz 1W Wireless Module...

Страница 2: ...Indication of UART output 7 5 2 2 Indication of wireless transmitting 7 5 2 3 Configuration procedure of module 8 5 6 4 Notes for AUX 8 6 OPERATING MODE 9 6 2 TRANSMISSION MODE MODE 0 10 6 3CONFIGURE...

Страница 3: ...gy Co Ltd E62 433T30D user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 2 10 PRODUCTION GUIDANCE 16 11 E62 SERIES 16 12 ANTENNA RECOMMENDATION 17 13 PACKAGE FOR BATCH ORDER 18...

Страница 4: ...transmission operation and it achieve a very low latency communication link The module features FEC Forward Error Correction algorithm which ensure its high coding efficiency good correction performan...

Страница 5: ...voltage V 3 3 5 0 5 2 5 0 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 85 Industrial design Operating frequency MHz 425 450 5...

Страница 6: ...interface UART Package DIP Connector 2 54mm Size 37 60mm Antenna SMA K 50 ohm impedance 3 Size and pin definition No Name Direction Function 1 M0 Input weak pull up Work with M1 to decide 4 working m...

Страница 7: ...onnects to external RXD MCU PC input pin Can be configured as open drain or push pulloutput 5 AUX Output To indicate module s working status wakes up the external MCU During the procedure of self chec...

Страница 8: ...here are data that are not sent yet via wireless way or whether all wireless data has been sent through UART or whether the module is still in the process ofself check initialization 5 2 1 Indication...

Страница 9: ...UX outputs low level if none of the low level condition is met AUX outputs high level 2 When AUX outputs low level it means the module is busy cannot conduct operating mode checking Within 1ms since A...

Страница 10: ...through serial port it will start to work in new mode after thetransmitting finished Therefore the mode switch is only valid when AUX outputs 1 otherwiseit will delay 2 For example in mode 0 or mode...

Страница 11: ...ormat Illustration 1 C0 working parameters C0 5 bytes working parameters are sent in hexadecimal format 6 bytes in totaland must be send in succession Save the parameters when power down Type When M0...

Страница 12: ...el launch mode Baud rate Parity Transmitting power E62 433T30D 425 450 5MHz 1 10 64kbps 9600 8N1 1W 7 2 Reading operating parameters Instruction format Description C1 C1 C1 In parameter setting mode M...

Страница 13: ...ed for the occasion that need to change the operating parameters frequently such as C2 01 0A 1A 0A 44 No Item Description Notes 0 HEAD Fix 0xC0 or 0xC2 it means this frame data is control command Must...

Страница 14: ...tion parties The UART baud rate has nothing to do with wireless transmission parameters won t affect the wireless transmit receive features 0 is recommended The lower the air data rate the longer the...

Страница 15: ...is recommended After turn off FEC the actual data transmission rate increases while anti interference ability decreases Also the transmission distance is relatively short Both communication parties mu...

Страница 16: ...h large electromagnetic interference around the module that will greatly affect the performance It is recommended to keep them away from the module according to the strength ofthe interference If nece...

Страница 17: ...ensure the humidity is within limited range some parts are sensitive to humidity Please avoid using modules under too high or too low temperature 9 3 BER Bit Error Rate is high There are co channel si...

Страница 18: ...Flexible omnidirectional TX433 JWG 7 Rubber antenna 433M SMA J 2 5 75mm Flexible omnidirectional TX433 JK 20 Rubber antenna 433M SMA J 3 210mm Flexible omnidirectional TX433 JK 11 Rubber antenna 433M...

Страница 19: ...Chengdu Ebyte Electronic Technology Co Ltd E62 433T30D user manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 18 13 Package for batch order...

Страница 20: ...al version huaa 1 10 2018 01 30 module name change huaa 1 20 2018 10 25 version updating huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank...

Отзывы: