background image

Chengdu Ebyte Electronic Technology Co.,Ltd

E610-433T30S User Manual

Copyright ©2012–2022,

Chengdu Ebyte Electronic Technology Co.,Ltd

27

E70-900T30S

CC1310

868M/915M

30

6

SMD

24*38.5

TTL

Chapter Xv Antenna guidance

Antenna is an important role in the communication process, often poor antenna will cause a great impact on the

communication system, so our company recommends some antennas as supporting our wireless module with excellent
performance and reasonable price.

Product Mode

Type

Frequency

Hz

Interface

Gain

dBi

Height

mm

Feeder

cm

Function

TX433-FPC-5711

Soft

antenna

433M

IPEX-1

2.5

10.5*57

-

Built-in flexible,

FPC soft antenna

TX433-JZ-5

Rubber

antenna

433M

SMA-J

2.0

52

-

Ultrashort

straight,

omnidirectional

antenna

TX433-JZG-6

Rubber

antenna

433M

SMA-J

2.5

62

-

Ultrashort

straight,

omnidirectional

antenna

TX433-JW-5

Rubber

antenna

433M

SMA-J

2.0

50

-

Bend the glue stick,

omnidirectional

antenna

TX433-JWG-7

Rubber

antenna

433M

SMA-J

2.5

75

-

Bend the glue stick,

omnidirectional

antenna

TX433-JK-11

Rubber

antenna

433M

SMA-J

2.5

110

-

Bend the glue stick,

omnidirectional

antenna

TX433-JK-20

Rubber

antenna

433M

SMA-J

3.0

210

-

Bend the glue stick,

omnidirectional

antenna

TX433-XPL-100

Suker

Antenna

433M

SMA-J

3.5

185

100

Small suction cup

antenna,

cost-effective

TX433-XP-200

Suker

Antenna

433M

SMA-J

4.0

190

200

Neutral sucker

antenna, low loss

TX433-XPH-300

Suker

Antenna

433M

SMA-J

6.0

965

300

Large suction cup

antenna, high gain

Содержание E610-433T30S

Страница 1: ...E610 433T30S User Manual 433MHz 1W Wireless high speed connection module...

Страница 2: ...DETAILED FUNCTIONS 9 5 1FIXED POINT TRANSMISSION 9 5 2 BROADCASTING TRANSMISSION 9 5 3 BROADCASTING ADDRESS 10 5 4 LISTENING ADDRESS 10 5 5 MODULE RESET 10 5 6 AUX DETAILED DESCRIPTION 10 5 6 1 Seria...

Страница 3: ...DESCRIBES THE CONFIGURATION OF THE UPPER COMPUTER 21 CHAPTER X UPGRADE FIRMWARE 22 CHAPTER XI HARDWARE DESIGNING 23 CHAPTER XII FAQ 24 12 1 THE TRANSMISSION DISTANCE IS NOT IDEAL 24 12 2 MODULE DAMAGE...

Страница 4: ...ellectual property The test data obtained in this paper are all obtained by Ebai Laboratory and the actual results may be slightly different It is hereby stated that all trade names trademarks and reg...

Страница 5: ...munication allows users to set key and cannot be read greatly improve the user data privacy Support RSSI signal strength indicator function can be used to assess the signal quality improve the communi...

Страница 6: ...ser programmable control note 1 Measured distance km 2 Continuous transmission mode Clear and open space height 2 meters serial port baud rate 115200 note 2 10 General transmission mode Clear and open...

Страница 7: ...nuous mode Cache capacity byte 4096 Continuous mode can be regarded as unlimited capacity Modulation mode GFSK Gaussian frequency shift keying modulation Communication interface UART serial port TTL l...

Страница 8: ...ernal RXD input pin 5 RXD Input TTL serial port input connected to an external TXD output pin 6 M1 Input very weak pull up Cooperate with M0 to determine 4 working modes of the module not suspended bu...

Страница 9: ...gram Item A brief description of the connection between the module and the single chip microcomputer the figure above takes the STM8L single chip microcomputer as an example 1 The wireless serial port...

Страница 10: ...byte Electronic Technology Co Ltd E610 433T30S User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 9 Chapter Detailed functions 5 1Fixed point transmission 5 2 Broadcasting tran...

Страница 11: ...hardware self check as well as set the working mode according to user parameters In this process AUX keeps a low level and after completion AUX outputs a high level and starts to work normally accord...

Страница 12: ...you go the buffer size can be considered infinite Note AUX 1 does not mean that all serial port data of the module has been transmitted through wireless or the last package of data may be transmitted...

Страница 13: ...itches mode 5 6 6 Notes Number AUX Notes 1 For function 1 and function 2 above the output low level is preferred that is if any output low level condition is met AUX will output low level AUX outputs...

Страница 14: ...l port data of the module has not been transmitted wirelessly it can only enter the new working mode after the transmission is completed If the module receives wireless data and sends out data through...

Страница 15: ...on 6 2 Continuous transmission mode mode 0 Type M0 0 M1 0 Continuous transmission mode mode 0 Tran scei ve Automatically calculate the air rate required for continuous transmission according to the us...

Страница 16: ...upported Item Command Detailed description 1 Set register Instruction C0 start address length parameter Response C1 start address length parameter Example 1 Set the channel to 0x09 Instruction start a...

Страница 17: ...2 Register description Item Read w rite NAME Description Notes 00H Read w rite ADDH ADDH Default 0 Module addresses high and low bytes Note When the module address is equal to FFFF it can be used as t...

Страница 18: ...5K 0 0 0 1 1 5 5K 0 0 1 0 0 6 5K 0 0 1 0 1 11K 0 0 1 1 0 13K 0 0 1 1 1 21K 0 1 0 0 0 26K 0 1 0 0 1 42K 0 1 0 1 0 51K 0 1 0 1 1 82K 0 1 1 0 0 76K 0 1 1 0 1 125K 0 1 1 1 0 160K 0 1 1 1 1 410K 1 0 0 0 0...

Страница 19: ...tput the first frame of data from the sending end after 3ms 0 Distance first default 1 Speed first 1 0 Transmitted power The relationship between power and current is nonlinear and the efficiency of t...

Страница 20: ...fixed point mode together That is the destination address is different from the source address 0 Applicable only to general transmission mode 1 ON 4 3 2 1 0 Save 07H Write CRYPT_H Key height byte def...

Страница 21: ...eters during which AUX output is low Description of trunk networking rules 1 Forwarding rules The trunk can forward data bidirectional between two NeTiDs 2 In trunk mode ADDH ADDL serves as NETID inst...

Страница 22: ...D and key are displayed in decimal mode The value ranges of each parameter Network address 0 65535 Frequency channel 0 83 Network ID 0 255 key 0 65535 When configuring the trunk mode on the upper comp...

Страница 23: ...X GND module and control the M0 M1 level to enter configuration mode Select the Firmware Upgrade TAB in the configuration tool of the official website click the Open File button to select the firmware...

Страница 24: ...d with copper and grounded the top Layer of the contact part of the module must be close to the digital part of the module and route the cables in the Bottom Layer Assuming modules are welded or place...

Страница 25: ...ge to send power is smaller The matching degree between antenna and module is poor or the quality of antenna itself is wrong 12 2 Module damage Please check the power supply ensure the recommended bet...

Страница 26: ...Max 3 seconds Max Liquid phase temperature TL 183 217 TL above retention time 60 90 seconds 60 90 seconds Package peak temperature Tp Users should not exceed the temperature indicated on the moisture...

Страница 27: ...33M 30 1 DIP 21 36 TTL E34 2G4H11S 2 4G 11 0 13 SMD 12 19 TTL E34 2G4D11S 2 4G 11 0 13 SMD 12 19 TTL E34 2G4H20D nRF24L01 2 4G 20 2 5 DIP 21 36 TTL E34 2G4D20D nRF24L01 2 4G 20 2 5 DIP 21 36 TTL E34 2...

Страница 28: ...FPC soft antenna TX433 JZ 5 Rubber antenna 433M SMA J 2 0 52 Ultrashort straight omnidirectional antenna TX433 JZG 6 Rubber antenna 433M SMA J 2 5 62 Ultrashort straight omnidirectional antenna TX433...

Страница 29: ...hnology Co Ltd E610 433T30S User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 28 Chapter XVI Batch packaging Revise History Version Revise date Revise notes maintainer 1 0 202...

Страница 30: ...ngdu Ebyte Electronic Technology Co Ltd 29 About us Company Sales Hotline 4000 330 990 Tel 028 61543675 Technical support support cdebyte com Official website https www es ebyte com Company Address Bu...

Отзывы: