Chengdu Ebyte Electronic Technology Co.,Ltd.
E610-433TxxS User Manual
Copyright ©2012–2023
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
7
Air Rate
kbps
0.5 ~ 470
User-programmable control [Note 1]
Measured
distance
km
2 (continuous
transmission
mode)
1 (continuous
transmission mode)
Clear and open, height 2m, serial baud rate
115200 [Note 2]
10 (general
transmission
mode)
6 (general
transmission mode)
Clear and empty, height 2m, air rate 1.5kbps
Note 1: Valid in general transmission mode.
Note 2: In continuous transmission mode, the module automatically calculates and matches the over-the-air
rate by means of the serial port baud rate.
2.2 Working parameters
2.3 Working parameters
Hardware
parameters
Unit
Description
Remark
E610-433T30S
E610-433T20S
Packet length byte
55
No limit on package length in
continuous mode
Cache
capacity
byte
4096
Seen as unlimited capacity in
continuous mode
Modulation
method
-
GFSK
Gaussian
frequency
shift
key
modulation
Electrical
parameters
Unit
Performance
Remark
E610-433T30S E610-433T20S
Operating
voltage
V
3.0 ~ 3.6
1.8 ~ 3.6
≥3.3V for guaranteed output power, exceeding
3.6V will permanently damage the module
Communicati
on level
V
3.3
Risk of burn-in with 5V TTL
Transmitting
current
mA
1000
125
Instantaneous power consumption
Receiving
current
mA
40
38
Sleeping
current
uA
2.0
Software shutdown
Operating
temperature
℃
-40 ~ +85
Industrial
Storage
temperature
℃
-40 ~ +125
Industrial