Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co., Ltd.
18
In the configuration PC, the module address and frequency channel are displayed in decimal mode, and the range of
parameters is:
Module Address
:
0
~
65535
Frequency Channel
:
0
~
255
9. Hardware Design
It is recommended to use DC stabilized power supply to supply power to the module. The power supply ripple
coefficient is as small as possible, and the module needs to be reliably grounded.
Please pay attention to the correct connection of the positive and negative poles of the power supply. If the reverse
connection is connected, the module may be permanently damaged.
Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum,
the module will be permanently damaged.
Please check the stability of the power supply, the voltage can not be significantly frequent.
When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, and the whole machine is beneficial for long-term stable operation.
The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference.
High-frequency digital traces, high-frequency analog traces, and power traces must be avoided under the module. If
it is necessary to pass through the module, assume that the module is soldered to the Top Layer, and the copper is