Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2018, Chengdu Ebyte Electronic Technology Co.,Ltd.
6
5.2.3.Configuration procedure of module
Only happened when power-on resetting or exiting sleep mode.
5.2.4. Notes for AUX
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means if it
meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX outputs
high level.
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms since AUX
outputs high level, the mode switch will be completed.
After switching to new operating mode, it won’t be work in the new mode immediately until AUX rising edge 2ms later. If
AUX is on the high level, the operating mode switch can be effected immediately.
When the user switches to other operating modes from mode 3 (sleep mode) or it’s still in reset process, the module will reset
user parameters, during which AUX outputs low level.
6. Operating mode
The module has 4 operation mode, which decided by the status of M1 & M0. Below are the details:
Mode
(
0-3
)
M0
M1
Description
Remark
Mode 0
Half-Duplex
0
0
UART and wireless channel are open,
transparent transmission is on
,
half- duplex
operation
The receiver must work at same address,
channel and same baud rate.
Mode 1
Full-Duplex
1
0
UART and wireless channel are open,
transparent transmission is on
,
full- duplex
operation
The receiver must work at same address,
channel and same baud rate.
Mode 2
Reservation Mode
0
1
Reservation Mode
The same as that in mode 0.
Mode 3
Setting Mode
1
1
Parameter setting